Schneider Electric A9V11340

Schneider Electric A9V11340 Vigi iC60 3P 40A 30mA RCD, obsol

MPN A9V11340
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 40 A, 30 mA, Type AC, 400-415 V AC, 50/60 Hz, clip-on DIN rail mount, IP20, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V11340 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width117 mm
Height91 mm
Operating temperature-5...60 °C

Product details

Rated 40 A with 30 mA sensitivity, it protects against sinusoidal AC fault currents in 3P (three-pole) circuits at 400-415 V AC, 50/60 Hz. The voltage-independent tripping technology means it operates without an external power supply, relying on the fault current itself to trigger the mechanism.

The 30 mA earth-leakage sensitivity is the standard threshold for personal protection against fatal electric shock — it trips before a fault current reaches a level that could cause ventricular fibrillation. The voltage-independent tripping is a reliability advantage: the device does not depend on the supply voltage to operate, so it provides protection even if the neutral is lost upstream. The 8/20 µs impulse withstand of 250 A confirms the device can survive transient surge currents without nuisance tripping or damage.

Clip-on mounting onto a DIN rail — standard 35 mm symmetrical rail. The device occupies 7 x 9 mm pitches, so the width is 117 mm for the 3P unit. Depth is 73.5 mm, height 91 mm. It is designed as an outgoer device, meaning it sits on the load side of the breaker. The electrical connection to the MCB is by screws; bottom terminals are tunnel type accepting 1-35 mm² rigid or 1-25 mm² flexible cable. The comb busbar and distribution block compatibility is confirmed for the bottom side.

The local trip indicator provides a visual confirmation of the tripped state, aiding fault-finding on the panel.

MPN
A9V11340