Skip to main content
Schneider Electric A9V14463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9V14463 Vigi iC60 4P 63A 300mA AC RCD, O

MPNA9V14463
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 4P, 63 A, 300 mA, AC type, instantaneous, 230…415 V AC, DIN rail clip-on, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9V14463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9V14463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Poles description4P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9V14463 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9V14463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end
Wire stripping length14 mm for bottom connection
Terminal tightening torque3.5 N.m bottom
Width135 mm
Height91 mm
Depth73.5 mm
A9V14463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9V14463 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Schneider Electric A9V14463 is an Acti9 Vigi iC60 add-on residual current device (RCD) — 4 poles, rated 63 A, with a 300 mA AC-type earth-leakage sensitivity, instantaneous trip, for 230…415 V AC networks at 50/60 Hz.

The tunnel-type terminals on the bottom accept 1…35 mm² rigid or 1…25 mm² flexible cable, with a stripping length of 14 mm and a tightening torque of 3.5 N·m. The 4-pole unit occupies 7 modules of 9 mm pitch (135 mm width). IP20 on the body, IP40 inside a modular enclosure — suitable for dry indoor panel environments only.

The residual current tripping technology is voltage-independent, meaning it will still trip on a ground fault even if the line voltage is lost — a reliability advantage for safety circuits. The 8/20 µs impulse withstand rating of 250 A per IEC 61009-1 indicates it can survive surge events without nuisance tripping.

Frequently asked questions

Where can I buy A9V14463?

The A9V14463 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of A9V14463?

4-pole, 63 A rated current, 300 mA AC-type earth-leakage sensitivity, instantaneous trip, 230…415 V AC operational voltage, DIN rail mount, 73.5 mm depth.

What compliance documentation does Schneider provide for A9V14463?

The part is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. Rated insulation voltage 500 V AC, impulse withstand 6 kV per IEC 60947-2. Pollution degree 3. IP20/IP40 per IEC 60529.

MPN
A9V14463