Schneider Electric A9V35263

A9V35263 Vigi iC60 RCD Add-On Block, 2P 63A 300mA SI Type

MPN A9V35263
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 63 A, 300 mA, Type A-SI (Super Immunised), selective time delay, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V35263 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width72 mm
Height91 mm
Operating temperature-25...60 °C

Product details

It adds earth leakage protection to the circuit, with a rated residual sensitivity of 300 mA and a Type A-SI (Super Immunised) characteristic — meaning it handles pulsed DC earth faults and is immune to nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads.

Rated at 63 A (In) and 230…415 V AC (Ue), this 2-pole block is sized for the outgoing feeder of a single-phase or three-phase sub-distribution board. The selective (time-delayed) earth-leakage protection means it coordinates with downstream RCDs — it will hold during a momentary fault on a branch circuit, letting the downstream device clear first, then trip if the fault persists. This avoids a full-board blackout for a single branch fault. The voltage-independent residual current tripping technology means the RCD operates without needing a separate power supply; it uses the fault current itself to trigger the mechanism. This is a reliability advantage in installations where the neutral could be lost upstream.

The bottom tunnel terminals accept 1…35 mm² rigid or 1…25 mm² flexible cable, with a tightening torque of 3.5 N·m. The 14 mm strip length is standard for this terminal class. A comb busbar can feed the bottom terminals, simplifying multi-pole distribution.

Designed and certified to EN/IEC 61009-1 and EN/IEC 61009-2-1 (the RCD/MCB combination standards). Rated insulation voltage (Ui) 500 V AC, impulse withstand (Uimp) 6 kV. The 8/20 µs impulse withstand of 3000 A confirms it survives lightning-induced surge currents without damage.

MPN
A9V35263