Schneider Electric A9W11363 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9W11363 Vigi iC60, 63A 30mA AC Type, Obs

MPNA9W11363
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 63 A, 30 mA, Type AC, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9W11363 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W11363 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W11363 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W11363 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible
Wire stripping length14 mm
Terminal tightening torque3.5 N.m
Width117 mm
Height91 mm
Depth74 mm
A9W11363 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W11363 — Approvals
ParameterValue
StandardsEN 61009-1 IEC 61009-1

Product details

The Schneider Electric A9W11363 is a Vigi iC60 add-on residual current device (RCD) from the Acti9 range, rated 63 A with 30 mA earth-leakage sensitivity, Type AC.

The 63 A [In] rated current and 30 mA earth-leakage sensitivity, Type AC, mean this block protects a 3-phase outgoing circuit against sinusoidal AC earth faults up to 30 mA — standard for general-purpose socket-outlet and lighting circuits in commercial or light-industrial panels. The 400/415 V AC rated operational voltage (EN/IEC 61009-1) suits 3P networks up to 415 V line-to-line. Voltage-independent tripping means it operates without an external power supply, relying on the fault current itself. The 6 kV impulse withstand voltage (Uimp) covers typical surge coordination for distribution boards.

Clip-on mounting to DIN rail, 7 module pitches wide (9 mm each, so 63 mm). Tunnel-type terminals accept 1…35 mm² rigid or 1…25 mm² flexible cable; tighten to 3.5 N·m. IP20 on the device body, IP40 in a modular enclosure. Ambient operating range -5…60 °C; storage -40…85 °C. The trip indicator gives local signalling after a fault.

Frequently asked questions

How do I get current pricing and availability for A9W11363?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — this part is sourced through independent channels, not factory-direct.

What is the closest alternative to A9W11363 in the Vigi iC60 family?

The evidence does not list a direct successor order code. Look for a current-production Vigi iC60 add-on RCD with 3P, 63 A, 30 mA, Type AC — same DIN-rail footprint — and verify terminal compatibility with your existing iC60 MCB.

MPN
A9W11363