Specifications

A9W12463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W12463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230/415 V AC 50/60 Hz conforming to IEC 61009-1
Poles description4P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W12463 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W12463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible
Wire stripping length14 mm
Terminal tightening torque3.5 N.m
Width135 mm
Height91 mm
Depth74 mm
A9W12463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W12463 — Approvals
ParameterValue
StandardsIEC 61009-1 EN 61009-1

Product details

It provides earth-leakage protection for a 4-pole (4P) circuit rated at 63 A, with a 100 mA sensitivity and Type AC detection for sinusoidal AC fault currents. The unit is voltage-independent, meaning it trips on residual current alone without needing a separate power supply — a key reliability feature for downstream protection.

Mounts via clip-on onto a DIN rail, occupying 7 x 9 mm pitches (135 mm width total). The tunnel-type terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable on the downside, with a tightening torque of 3.5 N·m and a wire stripping length of 14 mm. The electrical connection to the upstream MCB is by screws, making it a straightforward add-on for panel builders integrating into an Acti9 distribution board.

Rated operational voltage is 230/415 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV per IEC 60947-2. Pollution degree 3 (conforming to IEC 60947-2) suits it for industrial control panels where conductive pollution may occur.

Frequently asked questions

Where can I buy A9W12463?

The A9W12463 is available to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time.

What are the key ratings of A9W12463?

The A9W12463 is a 4-pole add-on RCD rated at 63 A with 100 mA sensitivity, Type AC earth-leakage detection. It operates at 230/415 V AC, 50/60 Hz, and mounts on DIN rail.

What standards does A9W12463 comply with?

It complies with IEC 61009-1 and EN 61009-1 for residual current operated circuit-breakers, and IEC 60947-2 for insulation and impulse withstand requirements.

MPN