Schneider Electric A9W14363 — Residual Current Breakers (RCCB/RCBO)

A9W14363 Vigi iC60 Earth Leakage Add-on Block, 63A 300mA AC

MPNA9W14363
Obsolete

Schneider Electric Acti9 Vigi iC60, earth leakage add-on block, 3P, 63 A, 300 mA, AC type, clip-on DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9W14363 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W14363 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230/415 V AC 50/60 Hz conforming to IEC 61009-1
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W14363 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W14363 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible
Wire stripping length14 mm
Terminal tightening torque3.5 N.m
Width117 mm
Height91 mm
Depth74 mm
A9W14363 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W14363 — Approvals
ParameterValue
StandardsIEC 61009-1 EN 61009-1

Product details

It adds 300 mA AC-type earth leakage protection to a 3-pole 63 A circuit, tripping instantaneously when residual current exceeds that threshold.

Rated at 63 A (In) and 300 mA sensitivity, this block is sized for a subfeed or outgoing circuit where the upstream MCB is already 63 A — the add-on does not increase the interrupting rating, it adds leakage detection. Voltage-independent trip technology means the block operates without needing a separate power supply — it uses the line energy to trip.

Designed to IEC 61009-1 and EN 61009-1 (RCCB/MCB combination standards), with a rated insulation voltage of 500 V AC and rated operational voltage of 230/415 V AC at 50/60 Hz. Impulse withstand voltage is 6 kV per IEC 60947-2, and pollution degree 3 per the same standard. IP20 rated for the block body; IP40 in a modular enclosure.

Clip-on mount to DIN rail, 7 x 9 mm pitch modules wide (117 mm). The block connects to the iC60 MCB via screws — no busbar required, but the mechanical interlock is specific to the Vigi iC60 range.

The A9W14363 is marked obsolete by Schneider Electric. Any requalification for a substitute should account for the mechanical fit to the iC60 MCB and the AC-type trip characteristic.

Frequently asked questions

Where can I buy A9W14363?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of A9W14363?

63 A rated current, 300 mA earth leakage sensitivity, AC type, voltage-independent trip, instantaneous time delay, 230/415 V AC operational voltage, 6 kV impulse withstand.

What compliance standards does A9W14363 meet?

IEC 61009-1, EN 61009-1, and IEC 60947-2 (pollution degree 3).