Schneider Electric A9W21325 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9W21325 Acti9 Vigi iC60, 3P, 25A, 30mA,

MPNA9W21325
Active

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 3P, 25 A, 30 mA, Type A, instantaneous, 400/415 V AC, for iC60 double terminal.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9W21325 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W21325 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)400/415 V AC 50/60 Hz conforming to IEC 61009-1
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W21325 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W21325 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules6
Terminal connectionsTunnel type terminals downside 1...25 mm² rigid Tunnel type terminals downside 1...16 mm² flexible
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width108 mm
Height91 mm
Depth74 mm
A9W21325 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W21325 — Approvals
ParameterValue
StandardsIEC 61009-1 EN 61009-1

Product details

The A9W21325 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi iC60 range, designed to clip onto the outgoing side of an iC60 MCB with double terminals. It provides earth leakage protection for the downstream circuit without taking up extra DIN-rail space — the unit mounts directly onto the breaker via the screw connection. Rated 25 A with 30 mA sensitivity, Type A, instantaneous trip. The 30 mA threshold is the standard for personal protection against indirect contact in most IEC 60364 installations; it clears a fault before ventricular fibrillation becomes a risk.

The tunnel-type terminals on the downside accept 1...25 mm² rigid or 1...16 mm² flexible cable; strip length 14 mm, tighten to 2 N·m. IP20 body, IP40 within a modular enclosure — fine for a closed panel, not for washdown areas. The voltage-independent residual current tripping technology means the RCD operates without needing an external power supply — it uses the fault energy itself to trip. That's a reliability advantage in installations where a neutral loss could otherwise leave a powered RCD blind.

Frequently asked questions

What compliance standards does the A9W21325 meet?

It complies with IEC 61009-1 and EN 61009-1, plus IEC 60947-2 for the insulation and impulse withstand ratings. The IP ratings are IP20 per IEC 60529 and IP40 in a modular enclosure.

Where can I buy the A9W21325 and how is it quoted?

The A9W21325 is sourced and quoted to order against an RFQ through independent industrial-automation distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm commitment.

MPN
A9W21325