Schneider Electric A9W21463 — Residual Current Breakers (RCCB/RCBO)

A9W21463 Acti9 Vigi iC60, 4P, 63A, 30mA, Type A RCD

MPNA9W21463
Active

Schneider Electric Acti9 Vigi iC60 add-on residual current device, 4P, 63 A, Type A, 30 mA, instantaneous, 400/415 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9W21463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W21463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)400/415 V AC 50/60 Hz conforming to IEC 61009-1 400/415 V AC 50/60 Hz conforming to EN 61009-1
Poles description4P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W21463 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W21463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible
Wire stripping length14 mm
Terminal tightening torque3.5 N.m
Width135 mm
Height91 mm
Depth74 mm
A9W21463 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W21463 — Approvals
ParameterValue
StandardsIEC 61009-1 EN 61009-1

Product details

The A9W21463 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi iC60 range, designed to bolt onto the side of an iC60 MCB via the supplied screws. It gives you 4-pole earth leakage protection rated at 63 A with a 30 mA trip sensitivity, Type A waveform detection, and instantaneous response — no intentional delay. That 30 mA sensitivity covers the standard personnel protection threshold; Type A means it catches pulsating DC fault currents that a basic AC-only RCD would miss, which matters on circuits feeding electronics, VFDs, or single-phase rectified loads.

Clip-on DIN rail mounting, 7 module pitches wide (135 mm). The 74 mm depth keeps it flush with the MCB it attaches to, so no extra enclosure depth needed. Tunnel terminals on the bottom accept up to 35 mm² rigid or 25 mm² flexible cable; strip 14 mm and torque to 3.5 N·m. IP20 on the terminals, IP40 on the modular enclosure — fine for a clean panel, but it's not washdown-rated, so keep it inside the cabinet.

Rated operational voltage is 400/415 V AC, 50/60 Hz — standard 3-phase mains in most of Europe and many other regions.

Tripping technology — voltage independent

The residual current tripping is voltage independent. That means the RCD will trip on a ground fault even if the phase voltage collapses or the neutral is lost upstream — it doesn't need the grid voltage to power its electronics. That's a real safety advantage on a construction site or a temporary supply where you can't guarantee the neutral reference.

Frequently asked questions

Where can I buy A9W21463 and what is the lead time?

A9W21463 is sourced to order against an RFQ through our independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What standards does A9W21463 comply with?

A9W21463 complies with IEC 61009-1 and EN 61009-1 for RCDs, and IEC 60947-2 for the insulation and impulse withstand ratings.

What is the difference between A9W21463 and a standard iC60 RCD?

A9W21463 is an add-on residual current device that mounts to the side of an iC60 MCB via screws, sharing the same busbar connection. A standalone iC60 RCD (like the iC60 RCBO) integrates both overcurrent and earth leakage protection in one module. The A9W21463 approach lets you pair a specific MCB curve with the RCD, which is useful when you need different overcurrent protection characteristics on the same RCD-protected circuit.