Schneider Electric A9W26425

Schneider Electric A9W26425 Vigi iC60 RCD, 4P 25A 500mA Type

MPN A9W26425
Obsolete

Schneider Electric Acti9 Vigi iC60, add-on residual current device block, 4P, 25 A rated current, 500 mA sensitivity, Type A, clip-on DIN rail mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9W26425 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50/60 Hz conforming to EN 61009-1 230/415 V AC 50/60 Hz conforming to IEC 61009-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth74 mm
Width126 mm
Height91 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9W26425 is an Acti9 Vigi iC60 add-on residual current device (RCD) block — a 4-pole, 25 A, 500 mA sensitivity unit with Type A earth leakage protection. It clips onto the outgoing side of an iC60 MCB to add ground-fault detection to the circuit, tripping instantaneously when leakage exceeds the 500 mA threshold. The voltage-independent trip technology means it operates without needing an external power supply, relying on the fault current itself to trigger the mechanism.

Rated at 25 A continuous and 400 V AC (230/415 V AC per IEC 61009-1), this block is sized for a standard 4-pole outgoing circuit in a 50/60 Hz network. The 500 mA sensitivity is for equipment or fire protection where a higher leakage threshold is acceptable. IP20/IP40 protection means installation inside a panel.

The tunnel-type terminals accept 1–25 mm² rigid or 1–16 mm² flexible cable, with a 2 N·m tightening torque and 14 mm strip length. Screw connection to the upstream MCB means it's a mechanical add-on, not a bus-bar jumper; you'll need the matching iC60 breaker and the screws provided.

Designed and certified to IEC 61009-1 and EN 61009-1 (the combined MCB/RCD standard for residual current breakers with overcurrent protection integrated or as an add-on). The 8/20 µs impulse withstand of 250 A per IEC 61009-1 confirms it handles surge currents typical of lightning-induced transients without nuisance tripping.

MPN