Schneider Electric A9W31263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9W31263 Acti9 Vigi iC60, 2P, 63A, 30mA,

MPNA9W31263
Active

Schneider Electric Acti9 Vigi iC60 add-on RCD, 2P, 63 A, 30 mA, Type A-SI, instantaneous, 230/240 VAC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9W31263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W31263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230/240 V AC 50/60 Hz conforming to EN 61009-1
Poles description2P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W31263 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W31263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules4
Terminal connectionsTunnel type terminals downside 1...35 mm² rigid Tunnel type terminals downside 1...25 mm² flexible
Wire stripping length14 mm
Terminal tightening torque3.5 N.m
Width72 mm
Height91 mm
Depth74 mm
A9W31263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W31263 — Approvals
ParameterValue
StandardsIEC 61009-1 EN 61009-1

Product details

The Schneider Electric A9W31263 is an Acti9 Vigi iC60 add-on residual current device (RCD) that clips onto the side of an iC60 MCB — two-pole, rated 63 A, with a 30 mA earth-leakage sensitivity. It's a Type A-SI (Super Immunised) instantaneous trip, meaning it handles pulsed DC fault currents and high-frequency leakage from electronics without nuisance tripping. That SI suffix matters in environments with variable-speed drives or switching power supplies where standard Type A might false-trip.

The 63 A rating matches the upstream MCB's frame — you pair this RCD with a 63 A iC60 breaker, not a smaller one. The 30 mA sensitivity is the standard for personnel protection (shock) per IEC 61009-1. Type A-SI adds immunity to 8/20 µs surge currents up to 3000 A, so it won't trip on lightning or switching transients on the line. Voltage-independent tripping means it clears a ground fault even if the phase voltage collapses — no power supply needed for the trip coil.

It's an outgoer device, meaning it sits downstream of the main breaker, protecting a branch circuit.

Designed to IEC 61009-1 and EN 61009-1 — the IEC standard for RCDs with integral overcurrent protection (though this is an add-on, not a combined device). Rated insulation voltage (Ui) is 500 V AC, and impulse withstand (Uimp) is 6 kV.

Frequently asked questions

Where can I buy the A9W31263 and get a price?

The A9W31263 is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What does Type A-SI mean on this RCD?

Type A-SI (Super Immunised) means the device handles pulsed DC fault currents and is immune to high-frequency leakage from electronics like VFDs and switching power supplies, reducing false trips. It also withstands 8/20 µs surge currents up to 3000 A without tripping.

What is the A9W31263's depth?

The A9W31263 has a depth of 74 mm.

MPN
A9W31263