Schneider Electric A9W31425 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9W31425 Acti9 Vigi iC60, 4P, 25A, 30mA,

MPNA9W31425
Active

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9W31425, 4P, 25 A, 30 mA, Type A-SI (super immunised), instantaneous, 400/415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9W31425 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9W31425 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)400/415 V AC 50/60 Hz conforming to IEC 61009-1
Poles description4P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9W31425 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9W31425 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules6
Terminal connectionsTunnel type terminals downside 1...25 mm² rigid Tunnel type terminals downside 1...16 mm² flexible
Wire stripping length14 mm
Terminal tightening torque2 N.m
Width126 mm
Height91 mm
Depth74 mm
A9W31425 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9W31425 — Approvals
ParameterValue
StandardsEN 61009-1 IEC 61009-1

Product details

The Schneider Electric A9W31425 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to clip onto the downstream side of an iC60 miniature circuit breaker (MCB) via the double-terminal connection. It adds earth-leakage protection to an existing MCB without replacing the breaker itself — a clean retrofit for panel upgrades or code compliance. Rated at 25 A continuous, 400/415 V AC, with 30 mA sensitivity and Type A-SI (super immunised) earth leakage protection. The A-SI designation means it handles pulsed DC residual currents (Type A) plus high-frequency leakage from VFDs or switched-mode supplies without nuisance tripping — a common need on modern production lines with variable-speed drives. Tripping is instantaneous, voltage-independent, so it works even if the neutral is lost.

Clip-on mounting to DIN rail, 4 poles wide (126 mm width, 91 mm height, 74 mm depth). Occupies 6 module pitches of 9 mm each. Tightening torque 2 N·m, strip length 14 mm.

Compliant with EN 61009-1 and IEC 61009-1 for RCBOs (combined MCB/RCD). Rated insulation voltage 500 V AC, impulse withstand voltage 6 kV, pollution degree 3 per IEC 60947-2. The 8/20 µs impulse withstand of 3000 A means it survives lightning-induced surges on the line without damage.

Lifecycle status is Active — current production, no end-of-life notice. No direct successor needed; this is the standard add-on RCD for the iC60 platform.

Frequently asked questions

Where can I buy A9W31425 and how do I get a price?

The A9W31425 is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is A9W31425's listed depth?

The listed depth is 74 mm.

What is the A9W31425 used for?

It is an add-on residual current device (RCD) that clips onto a Schneider iC60 MCB to provide earth-leakage protection at 30 mA sensitivity, Type A-SI (super immunised) for immunity to nuisance tripping from VFDs and electronic loads.