Skip to main content
Schneider Electric A9XELC10 — Circuit Breaker Accessories

Schneider Electric A9XELC10 Acti9 PowerTag Link C, 110-230 V

MPNA9XELC10
Obsolete

Schneider Electric Acti9 PowerTag Link C, A9XELC10, smart communication module, Ethernet, 110-230 VAC, IP20/IP40, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9XELC10 — Identification
ParameterValue
Product / component typeSmart communication module
Product nameActi9 PowerTag Link
Range of productActi9
A9XELC10 — Protection & Performance
ParameterValue
Protection typeOvervoltage at 1 kV for ETHERNET Overvoltage at 0.5 kV for auxiliary supply
A9XELC10 — Mechanical
ParameterValue
Device short namePowerTag Link C
Usable 9 mm pitches6 useful
Width54 mm
Height85 mm
Depth62 mm
ColourWhite (RAL 9003)
A9XELC10 — Environmental
ParameterValue
IP degree of protectionIP20 IP40 (modular enclosure)
Pollution degree2
Operating ambient air temperature-25...55 °C
Storage ambient air temperature-40...85 °C
A9XELC10 — Approvals
ParameterValue
StandardsEN 300-328 EN 301-489-1 EN 301-489-17 EN/IEC 60950-1

Product details

The Schneider Electric A9XELC10 is an Acti9 PowerTag Link C smart communication module — a DIN-rail mounted gateway that bridges wireless energy sensors (PowerTag 20, 2.4 GHz) to an Ethernet network for basic energy metering and load alarming. It sits in the Acti9 range, designed for final-distribution panels where you need per-circuit energy visibility without running separate wiring to each load.

Rated supply voltage is 110...230 V AC (+15 %), so it taps directly from the panel bus — no separate 24 VDC supply needed. The auxiliary supply is also accepted over 19.2...28.8 V DC if your panel runs a DC bus. Communication is Ethernet upstream to the cloud; commissioning runs over Bluetooth via the MySchneider Electrician or eSetup app. The front-face factory reset lets you clear the module back to defaults without a ladder or PC. Mounts horizontal or vertical on DIN rail; dimensions 85 x 54 x 62 mm (H x W x D).

The module carries declarations to EN 300-328 (radio), EN 301-489-1 and -17 (EMC), and EN/IEC 60950-1 (safety). Fire resistance on connection terminals is 960 °C for 30 s per IEC 60695-2; other parts meet 650 °C for 30 s. Tropicalisation to class 2 per IEC 60068-2, corrosive environment class 3C2 per IEC 60721-3-3, and salt mist class 2 per IEC 60068-2-52 are documented — relevant if the panel sits in a coastal or humid plant environment.

Frequently asked questions

What standards does the A9XELC10 comply with?

It carries declarations to EN 300-328, EN 301-489-1, EN 301-489-17, and EN/IEC 60950-1. Fire resistance, tropicalisation, and corrosive-environment ratings are also documented.

Where can I buy the A9XELC10 and get current pricing?

The A9XELC10 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the supply voltage range for this module?

Rated supply voltage is 110...230 V AC (+15 %). An auxiliary supply of 19.2...28.8 V DC is also accepted.

MPN
A9XELC10