Skip to main content
Schneider Electric A9XPP712 — Circuit Breaker Accessories

A9XPP712 Acti9 Comb Busbar, 63 A, 12 Modules, 3P+N

MPNA9XPP712
Active

Schneider Electric Acti9 comb busbar, A9XPP712, 3P+N balanced, 9 mm pitch, 12 modules, 63 A at 40 °C.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9XPP712 — Identification
ParameterValue
Product / component typeComb busbar
Product rangeActi9

Electrical

A9XPP712 — Electrical
ParameterValue
Rated operational voltage [Ue]230 V AC Ph/N 400 V AC Ph/Ph
Rated insulation voltage [Ui]440 V AC conforming to IEC 61439-1
Rated impulse withstand voltage [Uimp]4 kV

Mechanical

A9XPP712 — Mechanical
ParameterValue
Connections / terminalsScrew terminals
Connection pitch9 mm between phase and neutral 18 mm between phases
Mounting modeHorizontal
Usable 9 mm pitches24
Width218 mm
ColourWhite (RAL 9003)

Environmental

A9XPP712 — Environmental
ParameterValue
IP degree of protectionIP20 with end-pieces and tooth covers
Pollution degree3 conforming to EN/IEC 60439-1

Approvals

A9XPP712 — Approvals
ParameterValue
StandardsEN/IEC 61439-1

Product details

The Schneider Electric A9XPP712 is a cuttable comb busbar from the Acti9 range, configured as 3P+N balanced with a 9 mm pitch between phase and neutral and 18 mm between phases. It spans 12 modules (218 mm width) and is rated for 63 A at 40 °C ambient, with a rated operational voltage of 230 V AC phase-to-neutral and 400 V AC phase-to-phase. The busbar distributes power across four ways (N N L2 N L3) in a horizontal mounting orientation, using screw terminals and tooth-type connectors. It is designed for top mounting on tunnel-type terminals within Acti9 distribution boards.

The 63 A rated operational current at 40 °C defines the continuous load the busbar can carry in a typical panel environment. For higher ambient temperatures, derating applies per IEC 61439-1 — the standard this busbar complies with. The rated insulation voltage of 440 V AC and impulse withstand voltage of 4 kV confirm the busbar is suitable for 400 V three-phase systems with adequate clearance and creepage margins. The 9 mm pitch between phase and neutral terminals matches the standard spacing of Acti9 miniature circuit breakers and residual current devices, ensuring direct mechanical and electrical connection without adapters. The 18 mm spacing between phases accommodates the wider footprint of 3P devices.

This busbar is intended for horizontal mounting inside Acti9 distribution boards, connecting the line-side terminals of DIN-rail mounted devices. It is cuttable to length, allowing the installer to trim off unused modules for a clean fit in smaller enclosures. With IP20 protection when end-pieces and tooth covers are fitted, it is suitable for installation inside a closed panel. The white RAL 9003 finish matches the standard Acti9 aesthetic.

Frequently asked questions

Where can I buy A9XPP712 and how do I get a price?

The A9XPP712 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is A9XPP712's listed range on this component line?

The A9XPP712 belongs to the Schneider Electric Acti9 range.

What is A9XPP712's listed width?

The A9XPP712 has a width of 218 mm, which corresponds to 12 modules of 18 mm each.

What compliance documentation does this brand provide for A9XPP712?

The A9XPP712 complies with EN/IEC 61439-1 for low-voltage switchgear and controlgear assemblies, and with IEC 60695-2-1 for glow-wire fire resistance at 960 °C for 30 seconds. Pollution degree 3 per EN/IEC 60439-1 is also declared.

MPN
A9XPP712