Skip to main content
Schneider Electric A9Y70625 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Y70625 Acti9 Vigi iCG40, 25 A 30 mA RCB

MPNA9Y70625
Active

Schneider Electric Acti9 Vigi iCG40, add-on residual current device, 1P+N, 25 A, 30 mA Type A, 230 V AC, DIN rail clip-on, IP20.

$268.70Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Y70625 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationFault indication
A9Y70625 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated impulse withstand voltage (Uimp)4 kV conforming to EN/IEC 61009-2-1
Device location in systemGroup incomer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Y70625 — Identification
ParameterValue
Product nameActi9 Vigi iCG40
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iCG40
A9Y70625 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules2
Terminal connectionsTunnel type terminal top 1...16 mm² rigid Tunnel type terminal top 1...10 mm² flexible
Wire stripping length14 mm for top connection
Terminal tightening torque2 N.m top
Width36 mm
Height102.5 mm
Depth74 mm
A9Y70625 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 61009-2-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9Y70625 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

It is rated 25 A with a 30 mA sensitivity, Type A (pulsating DC and sinusoidal AC fault detection), and operates at 230 V AC 50/60 Hz in a 1P+N pole configuration. For a panel OEM or MRO planner: this is the add-on module, not a standalone RCBO — it needs a mechanical and electrical link to an Acti9 MCB (screw connection). The 30 mA trip threshold suits standard socket-outlet and lighting circuit protection in residential or commercial distribution boards. Type A covers electronic loads like washing machines, LED drivers, and IT equipment that generate pulsed DC fault currents — a common requirement in modern installations.

Depth is 74 mm, height 102.5 mm — standard for the Acti9 modular range. Terminal tunnel accepts 1–16 mm² rigid or 1–10 mm² flexible; strip length 14 mm, tighten to 2 N·m. IP20 finger-safe front; the modular enclosure is rated IP40 inside the panel.

Frequently asked questions

What is the A9Y70625 used for?

It is an add-on residual current device (RCBO module) that clips onto an Acti9 MCB to provide earth-leakage protection at 30 mA Type A for 25 A circuits, typically in residential or commercial distribution boards.

How do I get current pricing and availability for A9Y70625?

Submit an RFQ through the storefront — the part is sourced to order via independent distribution, and pricing with current availability is confirmed at quote time.

MPN
A9Y70625