Skip to main content
Schneider Electric A9Y76640

Schneider Electric A9Y76640 Acti9 Vigi iCG40, 40A, 300mA, A-

MPN A9Y76640
Active

Schneider Electric Acti9 Vigi iCG40, add-on residual current device, 1P+N, 40 A, 300 mA, Type A-SI selective, 230 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y76640 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width36 mm
Height102.5 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9Y76640 is an Acti9 Vigi iCG40 add-on residual current device — a voltage-independent, 1P+N unit rated 40 A with 300 mA earth-leakage sensitivity. It clips onto the DIN rail alongside the corresponding MCB, connected by screws, and serves as a group incomer in a distribution board. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and resists nuisance tripping from upstream surge arrestors or variable-speed drives, which is the main reason you'd pick this over a standard Type A.

The 300 mA sensitivity is selective (time-delayed), so it coordinates with downstream 30 mA RCDs: the downstream unit trips first on a person-contact fault, while this one only clears on insulation faults or cumulative leakage. That selectivity saves you chasing a whole-board blackout when a single socket RCD trips. Voltage-independent tripping means the RCD operates even if the neutral is lost upstream — the fault energy itself powers the trip mechanism. That is a safety-relevant feature for group incomers where you cannot guarantee the supply voltage under fault conditions. Clip-on mounting on standard DIN rail, 2 x 9 mm pitches wide (18 mm). IP20 body, IP40 inside a modular enclosure — fine for dry indoor distribution boards, not for washdown areas.

MPN
A9Y76640