Skip to main content
Schneider Electric A9Y80640

Schneider Electric A9Y80640 Acti9 Vigi iC40, 40A 30mA RCD

MPN A9Y80640
Active

Schneider Electric Acti9 Vigi iC40, add-on residual current device, 40 A, 30 mA, Type A, 1P+N, 230 V AC, DIN rail mount, white.

$326.38 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9Y80640 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 61009-2-1
ColorWhite
Depth74 mm
Width36 mm
Height95 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

Add-on RCD for Acti9 MCB line

The Schneider Electric A9Y80640 is an add-on residual current device from the Acti9 Vigi iC40 range, designed to clip onto the outgoing side of a compatible Acti9 miniature circuit breaker. Mounting is clip-on to DIN rail, occupying 2 modules of 9 mm pitch (18 mm total width). Rated operational voltage is 230 V AC at 50/60 Hz, with an insulation voltage of 400 V AC and impulse withstand of 4 kV per EN/IEC 61009-2-1.

The 30 mA sensitivity is the standard threshold for personal protection against fatal electric shock — it clears a fault before heart fibrillation can occur. The instantaneous trip (no intentional time delay) means it operates within 300 ms on a solid ground fault, which is appropriate for final subcircuits. Type A detection covers the rectified DC pulses from single-phase power supplies (computers, LED drivers, VFDs), so this unit is suitable for general-purpose socket outlets and lighting circuits in commercial or residential panels. Rated current of 40 A matches a 40 A MCB upstream — do not oversize the RCD relative to the breaker, as the RCD's own current-carrying capacity must equal or exceed the circuit rating. The voltage-independent tripping mechanism means the device does not rely on the mains voltage to detect a fault; it uses the fault current itself to energize the trip coil, so it remains functional even if the neutral is lost upstream.

Clip-on mounting to DIN rail (EN 60715) and 2-module width make this a straightforward addition to an existing Acti9 distribution board. The tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable, with a stripping length of 14 mm and tightening torque of 2 N·m. Ambient operating range is -25 to 60 °C, storage -40 to 85 °C, with up to 95% relative humidity at 55 °C — adequate for enclosed panel environments but not for direct outdoor exposure. IP20 rated (finger-safe) for the device body; IP40 when installed in a modular enclosure. Maximum operating altitude is 2000 m without derating.

MPN