Skip to main content
Schneider Electric ABLU3A24200

Schneider Electric ABLU3A24200

MPNABLU3A24200
Active

Industrial, DIN Rail Power Supplies

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ABLU3A24200 key specifications
ParameterValue
Range of productModicon Power Supply
Power supply typeRegulated switch mode
Input protection typeIntegrated fuse (not interchangeable) 3.15 A External protection (recommended)
Output protection typeAgainst overload and short-circuits, protection technology: manual or automatic reset by switch Against over temperature, protection technology: automatic reset Against overvoltage, protection technology: manual reset
Product or component typePower supply
Output voltage24 V DC
Nominal input voltage380...500 V AC three phase
Output voltage adjustment24...28 V
Inrush current35 A 380 V 35 A 500 V
Current consumption< 0.85 A 380 V AC < 0.73 A 500 V AC
Maximum leakage current2 mA 500 V AC
Power supply output current20 A

All specifications

ABLU3A24200 additional specifications
ParameterValue
Permissible temporary current boost1.5 x In for 5 seconds)
Power factor0.90 at 380 V AC 0.88 at 500 V AC
Rated power in480 W
Power dissipation in33 W
Nominal network frequency50...60 Hz
Enclosure materialMetal
IP degree of protectionIP20
Mounting supportTop hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 Double-profile DIN rail
Connections - terminalsScrew connection 4...6 mm², AWG 12...AWG 10) without wire end ferrule output Screw connection 4 mm², AWG 12) with wire end ferrule output Screw connection 0.75...6 mm², AWG 18...AWG 12) without wire end ferrule input Screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule input Cage clamp 0.2...1.5 mm², AWG 22...AWG 16) without wire end ferrule diagnostic relay Cage clamp 0.2...0.75 mm², AWG 22...AWG 18) with wire end ferrule diagnostic relay Cage clamp 0.2...0.75 mm², AWG 22...AWG 18) with wire end ferrule shut down input
Pollution degree2
Shock resistance150 m/s² 11 ms
Operating altitude< 5000 m overvoltage category III overvoltage category II
Vibration resistance3.5 mm (f= 3...11.9 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 11.9...150 Hz) conforming to IEC 60068-2-6
Electrical shock protection classClass I
Depth5.01 in (127.3 mm)
Width2.6 in (65 mm)
Height4.9 in (124 mm)
Meantime between failure [MTBF]876500 h at 77 °F (25 °C), full load conforming to SR 332 374800 h at 131 °F (55 °C), 80 % load conforming to SR 332
StandardsIEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 CSA C22.2 No. 107.1
SupplySELV IEC 60950-1 SELV IEC 60204-1 SELV IEC 60364-4-41
MarkingCE UKCA
CategoryUS1CP1222524
Efficiency93 % 380 V AC 93 % 500 V AC
Status LED1 LED (green and red) product status
Holding time> 20 ms 380 V AC > 20 ms 500 V AC
Service life10 year(s) 104 °F (40 °C) 80 % load
Turn-on time< 1 s
Variant optionUniversal
Output couplingParallel
Residual ripple< 150 mV
Diagnostic relayElectromechanical relay 1000.0 mA 30 V
Dielectric strength4000 V AC with input to output 2000 V AC with input to ground 1500 V AC with output to ground 4000 V AC with input to diagnostic relay 500 V AC with output to diagnostic relay 1500 V AC with diagnostic relay to ground with shutdown input not isolated from output
Overvoltage categoryIII II
Efficiency at full load320...575 V AC 3 phase
Electromagnetic emissionConducted emissions IEC 61000-6-3 Radiated emissions IEC 61000-6-4
Electromagnetic immunityImmunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1
Line and load regulation< 0.17 % network 100 % load in line at 77 °F (25 °C) < 0.6 % +/- 0.5 % network 150 % load at 77 °F (25 °C)
Network system compatibilityTN TT IT
Startup with capacitive loads200000 µF
Ambient air temperature for operation-13...131 °F (-25...55 °C) without current derating mounting position A < 6561.68 ft (2000 m) 131...158 °F (55...70 °C) with current derating of 3.3 % per °C mounting position A < 6561.68 ft (2000 m)
MPN