APMCA03LCY6RH — Identification
ParameterValue
Product range / seriesAltivar Process Modular
Device short name / model codeAPM
Product / component typePower filter
APMCA03LCY6RH — Electrical (input)
ParameterValue
Rated supply voltage500...690 V - 10...10 %
Network phases3 phases
Line (input) current200 A at 500 V (normal duty) 200 A at 690 V (normal duty) 163 A at 500 V (heavy duty) 163 A at 690 V (heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated with 300 m category C3
Max. input current THD (THDi)<48 % full load conforming to IEC 61000-3-12
APMCA03LCY6RH — Output / Performance
ParameterValue
Apparent power239 kVA normal duty 195 kVA heavy duty
APMCA03LCY6RH — Mechanical
ParameterValue
Mounting modeCabinet mount
APMCA03LCY6RH — Environmental
ParameterValue
IP rating (with kit options)IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529
Operating ambient temperature-10...40 °C (without derating) 40...50 °C (with derating factor)
Storage temperature-40...70 °C
Operating altitude (with derating)<= 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Pollution degree2 conforming to IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn for 11 ms conforming to IEC 60068-2-27
APMCA03LCY6RH — Approvals & Compliance
ParameterValue
StandardsUL 61800-5-1 IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Agency markings / approvalsCE

Product details

The Schneider Electric APMCA03LCY6RH is a power filter in the Altivar Process Modular (APM) family, designed to sit between the supply and the drive for a cabinet-mounted installation. Heavy-duty rating drops to 163 A at the same voltages, 195 kVA. The integrated EMC filter meets category C3 for 300 m cable runs, which covers most industrial motor cable lengths without an external filter.

Sizing and fit constraints

At 1249 mm high, 269 mm wide, and 506 mm deep, this is a floor-standing cabinet section, not a DIN-rail component. The IP00 enclosure means it expects a clean, dry environment inside the cabinet — no hose-down, no dust ingress protection. Operating altitude is limited to 2000 m with derating above 1000 m; ambient temperature range is -10 to 40 °C without derating, 40 to 50 °C with a derating factor. Mounting is vertical only, integrated into the cabinet structure.

Compliance and environment

The part carries CE marking and complies with a full suite of IEC and UL standards: UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Pollution degree 2, vibration and shock resistance per IEC 60068-2-6 and 60068-2-27. Chemical and dust pollution resistance class 3C3 / 3S3 per IEC 60721-3-3. The EMC immunity profile includes level 3 for electrostatic discharge, radiated RF, and conducted RF, and level 4 for fast transients. Prospective line short-circuit current rating is 50 kA. Insulation resistance is > 1 MΩ at 500 V between supply and earth.

Frequently asked questions

What compliance documentation does this part carry?

CE marking, UL 61800-5-1, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The EMC filter is integrated to category C3 for 300 m cable runs.

What are the key electrical ratings for the APMCA03LCY6RH?

Line current 200 A at both 500 V and 690 V normal duty (163 A heavy duty). Apparent power 239 kVA normal duty, 195 kVA heavy duty. Supply voltage 500...690 V -10...10 %, three-phase. Prospective line short-circuit current 50 kA.

What are the physical dimensions and mounting requirements?

Height 1249 mm, width 269 mm, depth 506 mm. Cabinet mount, vertical orientation only. IP00 protection. Ambient temperature -10 to 40 °C without derating, up to 50 °C with derating. Altitude up to 2000 m with derating above 1000 m.