Skip to main content
Schneider Electric ATH230D15M3 — AC Drive (VFD) 240V

Schneider Electric ATH230D15M3 Altivar HVAC Drive, 15 kW

MPNATH230D15M3
Active

Schneider Electric Altivar HVAC ATH200 series, ATH230D15M3 AC drive, 15 kW, 3-phase 200-240 V, cabinet mount, SIL 3 STO, BACnet/IP communication module.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH230D15M3 — Electrical Input
ParameterValue
Rated supply voltage200...240 V - 15...10 %
ATH230D15M3 — Electrical Output
ParameterValue
Motor power (normal / heavy duty)15 kW
ATH230D15M3 — Approvals
ParameterValue
Compliance standardsIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATH230D15M3 — Mechanical
ParameterValue
Height13.0 in (330 mm)
Width7.09 in (180 mm)

Product details

15 kW VFD for HVAC duty with integrated BACnet/IP

The ATH230D15M3 is a 15 kW Altivar HVAC ATH200 drive, 3-phase 200-240 V input, cabinet-mount, with a built-in BACnet/IP communication module and SIL 3 STO safety function. Rated line current is 79.7 A at 200 V and 67.1 A at 240 V, with an apparent power of 27.9 kVA at 240 V.

Safety and compliance package

Safety integrity is SIL 3 per IEC 61508 and PL = e per ISO 13849-1, with STO (safe torque off) as the safety function. Approvals include CULus, CE, UKCA, KC, EAC, ATEX, and RCM. The drive meets IEC 61800-5-1, IEC 61800-3 (environments 1 category C2 and 2 category C3), UL 508C, IEC 60721-3, and IEC 61508.

Application-specific functions and fieldbus

Built-in functions include fire mode, run permissive, PID controller with additional PID, damper control, and underload detection for broken belt — all configurable without an external controller. Fieldbus access is via Server Modbus serial and Subordinate BACnet MS/TP over a 2-wire RS 485 physical interface, with the BACnet/IP option card already fitted.

Physical fit and mounting

Supplied without an EMC filter — plan for external filtering if the installation requires conducted emission limits per IEC 61800-3 category C2 or C3.

Frequently asked questions

Where can I buy the ATH230D15M3 and get a price?

Sourced to order against your BOM quantity through independent distribution. Submit an RFQ for current pricing and availability.

What compliance documentation does Schneider Electric provide for the ATH230D15M3?

The drive carries CULus, CE, UKCA, KC, EAC, ATEX, and RCM markings. It complies with IEC 61800-5-1, IEC 61800-3, UL 508C, IEC 60721-3, IEC 61508, and ISO 13849-1.

MPN
ATH230D15M3