Skip to main content
Schneider Electric ATH230D15N4 — AC Drive (VFD) 480V

Schneider ATH230D15N4 Altivar AC Drive, 15 kW, 3-Phase 480 V

MPNATH230D15N4
Active

Schneider Electric Altivar HVAC ATH200 series, ATH230D15N4 AC drive, 15 kW, 3-phase 480 V, 47.3 A line current at 380 V, 33.3 A at 500 V, cabinet mount, 13.0 x 7.09 x 7.8 in.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH230D15N4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH230
Product range / familyAltivar HVAC ATH200
ATH230D15N4 — Power & Output
ParameterValue
Motor power (kW)15 kW
Max. transient current36.4 A
Apparent power28.8 kVA at 500 V
ATH230D15N4 — Input / Supply
ParameterValue
Rated supply voltage range380...500 V - 15...10 %
Input line current47.3 A 380 V 33.3 A 500 V
ATH230D15N4 — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH230D15N4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)22 kA
ATH230D15N4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20
Acoustic noise level58 dB
ATH230D15N4 — Environmental
ParameterValue
Operating ambient temperature14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor
Operating altitude3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Relative humidity5...95 % without condensation or dripping water EN/IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2
ATH230D15N4 — Approvals
ParameterValue
Certifications & markingCULus CE UKCA KC EAC ATEX RCM
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environment 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATH230D15N4 — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

15 kW HVAC drive with integrated safety and comms

The Schneider ATH230D15N4 is a 15 kW Altivar HVAC ATH200 drive built for 3-phase 480 V fan and pump loads. It pulls 47.3 A line current at 380 V and 33.3 A at 500 V, with an apparent power rating of 28.8 kVA at 500 V — sized for a 15 kW motor on a conveyor or AHU. The output frequency goes to 0.599 kHz, and the output voltage tracks the supply rail. This is the standard version, not a coated or high-protection variant.

SIL 3 STO and multi-standard compliance

Safety level is SIL 3 per IEC 61508 and PL = e per ISO 13849-1, with STO (safe torque off) on the discrete input. This lets the drive integrate into a safety circuit without an external contactor — the STO channel is monitored by the drive logic. Markings include CULus, CE, UKCA, KC, EAC, ATEX, and RCM. It complies with IEC 61800-5-1, IEC 61800-3 (environment 1 category C2 and environment 2 category C3), UL 508C, IEC 61508, and ISO 13849-1. The integrated EMC filter saves panel space on conducted emissions compliance.

Panel dimensions and mounting

Altitude derating starts at 3280 ft (1000 m): 1 % derating per 100 m above that. Pollution degree 2 environment, 5–95 % relative humidity without condensation.

Built-in BACnet and Modbus

The drive ships with a BACnet IP communication module on an option card slot, plus a 2-wire RS 485 physical interface running Modbus serial (RTU MS/TP) and BACnet MS/TP. Data rates go up to 76.8 kbit/s; addressing supports 0–247 for Modbus and 0–127 for BACnet. The RJ45 connector is the fieldbus drop. Built-in functions include fire mode, PID controller, damper control, and underload detection for broken belt — the HVAC-specific logic reduces the need for a separate building controller for simple sequences.

Frequently asked questions

What compliance documentation does Schneider provide for the ATH230D15N4?

The drive carries CULus, CE, UKCA, KC, EAC, ATEX, and RCM markings. It complies with IEC 61800-5-1, IEC 61800-3 (environments 1 and 2), UL 508C, IEC 61508, and ISO 13849-1. The integrated EMC filter covers conducted emissions for those standards. RoHS and REACH documentation is standard from Schneider for this series.

MPN
ATH230D15N4