ATH230D22N4 specifications
ParameterValue
Connector typeRJ45
Main product or component typeVariable speed drive
Current64.6 A 380 V 49.4 A 500 V
Frequency50...60 Hz - 5...5 %
Phases3-phase
IP ratingIP20
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-13...158 °F (-25...70 °C)
Pollution degree2
Depth9.02 in (229 mm)
Width7.09 in (180 mm)
Height15.4 in (390 mm)
Data format8 bits, configurable odd, even or no parity 1or 2 stop
Operating positionVertical +/- 10 degree
Operating temperature14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor

Product details

22 kW HVAC drive with STO and BACnet/IP

The ATH230D22N4 is a 22 kW Altivar HVAC ATH200 drive for 3-phase 480 V fan and pump loads. Rated line current is 64.6 A at 380 V and 49.4 A at 500 V, with 42.8 kVA apparent power at 500 V. This is the standard version — no coating or extended I/O — meant for clean indoor cabinet mounting. It carries integrated STO (Safe Torque Off) at SIL 3 / PL e, so it can serve in safety-rated applications without an external safety relay for the stop function. The integrated EMC filter meets IEC 61800-3 environment 1 category C2 and environment 2 category C3, covering both residential and industrial second-environment installations.

Built for fan and pump duty

The drive includes fire mode, run-permissive, PID controller, damper control, and underload detection for broken belt — all standard. The BACnet/IP communication module is an option card slot; the base unit has a 2-wire RS-485 physical interface supporting Modbus serial and BACnet MS/TP at 38.4 or 76.8 kbit/s. Cabinet mount, vertical +/- 10 degrees. Operating altitude is 1000 to 3000 m with 1% current derating per 100 m above 1000 m. Pollution degree 2, relative humidity 5-95% non-condensing. Noise level is 64 dB — expect audible fan noise in a quiet machine room.

MPN