Schneider Electric ATH630D30N4Z — AC Drive (VFD) 480V

Schneider Altivar ATH630D30N4Z HVAC Drive, 30 kW, 40 hp

MPNATH630D30N4Z
Active

Schneider Electric Altivar HVAC ATH630, ATH630D30N4Z, 30 kW normal duty / 40 hp, 380-480 V, 53.3 A line current, cabinet mount, 25.8 kg.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630D30N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630D30N4Z — Power & Output
ParameterValue
Motor power (kW)30 kW for normal duty 22 kW for heavy duty
Max. transient current67.7 A during 60 s (normal duty) 69.5 A during 60 s (heavy duty)
Apparent power38.2 kVA (normal duty) 29.8 kVA (heavy duty)
ATH630D30N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current53.3 A at 380 V (normal duty) 46 A at 480 V (normal duty) 40.5 A at 380 V (heavy duty) 35.8 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630D30N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630D30N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATH630D30N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00
Acoustic noise level63.5 dB
ATH630D30N4Z — Environmental
ParameterValue
Operating ambient temperature-15...50 °C without derating 50...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
ATH630D30N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630D30N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

The ATH630D30N4Z is a 30 kW normal-duty / 22 kW heavy-duty HVAC drive from the Altivar ATH600 series, built for fan, pump, and compressor loads in commercial building services. Line current at 380 V normal duty is 53.3 A; at 480 V heavy duty it drops to 35.8 A — the lower current at higher line voltage means the drive's thermal capacity is set by the 380 V normal-duty figure for sizing the input protection. Integrated Class C2 EMC filter means the drive meets the conducted-emission limits for the second environment (industrial) without an external filter, which simplifies panel layout and saves a DIN-rail slot. The STO (safe torque off) function is certified SIL 3 per IEC 61508 and PL e per ISO 13849-1, so it can be wired directly into a safety circuit that removes drive torque without a separate safety contactor — provided the control wiring meets the SIL 3 segregation rules.

Panel fit and fieldbus options

The drive ships with a 2-wire RS-485 physical interface supporting Modbus RTU and BACnet MS/TP at selectable baud rates up to 76.8 kbit/s — the native BACnet connectivity is what makes this an HVAC-specific variant rather than a general-purpose Altivar. Optional communication modules snap into the option-card slot for PROFINET, Ethernet IP/Modbus TCP, or BACnet IP — if the BMS backbone is Ethernet, order the appropriate card at the same time to avoid a second panel visit.

Frequently asked questions

What compliance documentation does Schneider provide for ATH630D30N4Z?

The drive carries CE, UKCA, CULus, EAC, RCM, ATEX, WEEE, RoHS, and KCC markings, and is certified to UL 61800-5-1, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and ISO 13849-1. RoHS and REACH declarations are standard with the shipment.

What are the key HVAC-specific functions of this drive?

The firmware includes fire mode, forced fire mode, PID controller with three additional PID loops, damper control, underload detection for broken belt, scroll compressor management, skipped frequencies, catch on the fly, and power monitoring — all built in, no option card required.