Schneider Electric ATH630D55N4Z — AC Drive (VFD) 480V

Schneider ATH630D55N4Z Altivar HVAC Drive, 55 kW, 480 V

MPNATH630D55N4Z
Active

Schneider Electric Altivar ATH600, ATH630D55N4Z AC drive, 55 kW normal duty / 45 kW heavy duty, 480 V, cabinet mount, 748 x 265 x 306.9 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630D55N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630D55N4Z — Power & Output
ParameterValue
Motor power (kW)55 kW for normal duty 45 kW for heavy duty
Max. transient current116.6 A during 60 s (normal duty) 132.0 A during 60 s (heavy duty)
Apparent power70.0 kVA (normal duty) 59.7 kVA (heavy duty)
ATH630D55N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current97.2 A at 380 V (normal duty) 84 A at 480 V (normal duty) 81.4 A at 380 V (heavy duty) 71.8 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630D55N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630D55N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C3 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATH630D55N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00
Acoustic noise level62.4 dB
ATH630D55N4Z — Environmental
ParameterValue
Operating ambient temperature-15...50 °C without derating 50...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
ATH630D55N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630D55N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

55 kW normal duty, 45 kW heavy duty – which rating fits your load

The ATH630D55N4Z is a standard-version Altivar HVAC ATH600 drive rated 55 kW (75 hp) for normal-duty fan/pump loads and 45 kW (60 hp) for heavy-duty constant-torque loads like conveyors or compressors. The line current at 380 V normal duty is 97.2 A; at 480 V heavy duty it drops to 71.8 A. That spread means you size the input protection and cabling for the higher normal-duty figure unless the application is exclusively heavy-duty.

Safety function and compliance package

Safe Torque Off (STO) is integrated to SIL 3 per IEC 61508 and PL e per ISO 13849-1 – no external safety relay needed for the stop function. The drive carries CE, UKCA, CULus, EAC, RCM, and ATEX markings, plus RoHS and WEEE. The integrated Class C3 EMC filter covers conducted emissions for industrial environments (second environment per EN/IEC 61800-3).

Application-specific functions built in

Fire mode, forced fire mode, run permissive, PID controller with three additional PID sets, damper control, underload detection for broken belt, scroll compressor management, skipped frequencies, catch on the fly, and power monitoring are all standard. The drive also supports cybersecure firmware update. These are not option cards – they are in the base firmware.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATH630D55N4Z?

The drive carries CE, UKCA, CULus, EAC, RCM, ATEX, WEEE, ROHS, and KCC markings. It complies with UL 61800-5-1, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and ISO 13849-1.

MPN
ATH630D55N4Z