Skip to main content
Schneider Electric ATH630D75N4Z — AC Drive (VFD) 480V

Schneider ATH630D75N4Z Altivar ATH600 VFD, 75 kW ND

MPNATH630D75N4Z
Active

Schneider Electric Altivar HVAC ATH600 ATH630 series AC drive, ATH630D75N4Z, 75 kW normal duty / 55 kW heavy duty, 480 V, IP20, cabinet mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630D75N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630D75N4Z — Power & Output
ParameterValue
Motor power (kW)75 kW for normal duty 55 kW for heavy duty
Max. transient current159.5 A during 60 s (normal duty) 159.0 A during 60 s (heavy duty)
Apparent power93.7 kVA (normal duty) 72.7 kVA (heavy duty)
ATH630D75N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current131.3 A at 380 V (normal duty) 113 A at 480 V (normal duty) 98.9 A at 380 V (heavy duty) 86.9 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630D75N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630D75N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C3 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATH630D75N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00
Acoustic noise level62.4 dB
ATH630D75N4Z — Environmental
ParameterValue
Operating ambient temperature-15...50 °C without derating 50...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
ATH630D75N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630D75N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

75 kW HVAC drive with integrated safety

The Schneider Electric ATH630D75N4Z is a 75 kW normal duty (55 kW heavy duty) AC drive from the Altivar HVAC ATH600 series, designed for variable-speed control of pumps, fans, and compressors in building HVAC and industrial air-handling systems. Rated for 131.3 A line current at 380 V (normal duty) and 86.9 A at 480 V (heavy duty), this drive handles the full range of motor loads up to 100 hp in standard applications.

Ratings that decide the fit

The dual-duty rating — 75 kW normal duty for variable-torque loads like centrifugal fans, 55 kW heavy duty for constant-torque loads like conveyors or screw compressors — means one drive covers both classes without oversizing. Integrated Safe Torque Off (STO) to SIL 3 / PL e eliminates the need for a separate safety contactor on the motor circuit, reducing panel wiring and cabinet space. Built-in Class C3 EMC filter meets EN/IEC 61800-3 for industrial environments — no external filter needed for most installations, saving a DIN-rail slot and a cable gland.

Application-specific functions

Fire mode, forced fire mode, and damper control are built into the firmware — no option card needed for smoke-extract or pressurisation sequences in life-safety systems. Underload detection for broken belt and scroll compressor management protect the driven equipment from mechanical faults before they cause motor damage. Catch on the fly lets the drive synchronise to a spinning motor after a momentary power loss — useful for fan banks where the rotor is still turning when the supply returns.

Sourcing and compliance

Carries CE, UKCA, CULus, EAC, RCM, ATEX, and KCC markings, with RoHS and WEEE compliance — accepted across European, North American, Eurasian, and Korean regulatory jurisdictions. Full documentation package includes UL 61800-5-1 and IEC 61800-3 certification, plus IEC 61508 SIL 3 safety case — the paperwork for a plant-wide safety audit is on file.

Frequently asked questions

What safety functions does the ATH630D75N4Z include?

Safe Torque Off (STO) rated SIL 3 per IEC 61508 and PL e per ISO 13849-1, eliminating the need for an external safety contactor in most guarding circuits.

What is the difference between normal duty and heavy duty on this drive?

Normal duty is 75 kW (100 hp) for variable-torque loads like centrifugal fans and pumps; heavy duty is 55 kW (75 hp) for constant-torque loads such as conveyors, screw compressors, or positive-displacement pumps.

MPN
ATH630D75N4Z