Skip to main content
Schneider Electric ATH630U15N4Z — AC Drive (VFD) 480V

Schneider ATH630U15N4Z Altivar HVAC Drive, 1.5 kW Normal Dut

MPNATH630U15N4Z
Active

Schneider Electric Altivar HVAC ATH600 series, ATH630U15N4Z, 1.5 kW normal duty / 0.75 kW heavy duty, 380-480 V, STO SIL 3, C2 EMC filter, cabinet mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630U15N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630U15N4Z — Power & Output
ParameterValue
Motor power (kW)1.5 kW for normal duty 0.75 kW for heavy duty
Max. transient current4.1 A during 60 s (normal duty) 3.3 A during 60 s (heavy duty)
Apparent power2.2 kVA (normal duty) 1.4 kVA (heavy duty)
ATH630U15N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current3.463 A at 380 V (normal duty) 2.7 A at 480 V (normal duty) 2 A at 380 V (heavy duty) 1.7 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630U15N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630U15N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)5 kA
ATH630U15N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20
Acoustic noise level47 dB
ATH630U15N4Z — Environmental
ParameterValue
Operating ambient temperature-15...50 °C without derating 50...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
ATH630U15N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630U15N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

The Schneider Electric ATH630U15N4Z is a current-production Altivar HVAC drive from the ATH600 series, sized for a 1.5 kW motor at normal duty or 0.75 kW at heavy duty on a 380-480 V three-phase supply. It carries a Class C2 EMC filter integrated, STO safety function rated SIL 3 / PL e, and the usual HVAC-specific firmware — fire mode, PID, damper control, scroll compressor management.

The normal-duty line current is 3.463 A at 380 V and 2.7 A at 480 V; heavy-duty drops to 2 A at 380 V and 1.7 A at 480 V. That 1.5 kW / 0.75 kW split is the key selection gate — if your motor is a constant-torque load (conveyor, positive-displacement pump), you size to the heavy-duty column; for variable-torque HVAC loads (fan, centrifugal pump), normal duty applies. The drive needs a 24 V DC external control supply (19...30 V) and provides internal 24 V for digital inputs and STO. Mounts in a cabinet, vertical position only, with derating above 1000 m altitude.

Frequently asked questions

What compliance documentation does this drive carry?

It carries CE, UKCA, CULus, EAC, RCM, ATEX, WEEE, RoHS, and KCC markings, and complies with UL 61800-5-1, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and ISO 13849-1.

What are the key ratings for this drive?

Motor power: 1.5 kW normal duty / 0.75 kW heavy duty. Line current: 3.463 A at 380 V normal duty, 2.7 A at 480 V normal duty. Safety: STO SIL 3 / PL e. EMC filter: Class C2 integrated. Supply: 380-480 V, 50/60 Hz.

MPN
ATH630U15N4Z