Skip to main content
Schneider Electric ATH630U30N4Z — AC Drive (VFD) 480V

Schneider Electric ATH630U30N4Z Altivar HVAC Drive, 3 hp, 3.

MPNATH630U30N4Z
Active

Schneider Electric Altivar HVAC ATH600, ATH630U30N4Z, standard version, 3.0 kW / 3 hp, 380-480 V, integrated Class C2 EMC filter, SIL 3 STO.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630U30N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630U30N4Z — Power & Output
ParameterValue
Motor power (kW)3.0 kW for normal duty 2.2 kW for heavy duty
Max. transient current7.9 A during 60 s (normal duty) 7.7 A during 60 s (heavy duty)
Apparent power3.8 kVA (normal duty) 3.0 kVA (heavy duty)
ATH630U30N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current5.371 A at 380 V (normal duty) 4.6 A at 480 V (normal duty) 4.2 A at 380 V (heavy duty) 3.6 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630U30N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630U30N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)5 kA
ATH630U30N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20
Acoustic noise level53 dB
ATH630U30N4Z — Environmental
ParameterValue
Operating ambient temperature-15...50 °C without derating 50...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
ATH630U30N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630U30N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

The ATH630U30N4Z is a standard version Altivar HVAC ATH600 drive sized for a 3.0 kW (normal duty) or 2.2 kW (heavy duty) motor on 380-480 V three-phase supply. Normal-duty line current draws 5.371 A at 380 V, 4.6 A at 480 V; heavy-duty draws 4.2 A at 380 V, 3.6 A at 480 V. Apparent power is 3.8 kVA normal duty, 3.0 kVA heavy duty. Integrated Class C2 EMC filter covers conducted emissions for most commercial installations without an external filter. Safe torque off (STO) is rated SIL 3 per IEC 61508 and PL e per ISO 13849-1, meeting machine safety requirements for unexpected startup prevention.

Integration notes

Cabinet-mount unit, 145 mm wide, 197 mm tall, 166 mm deep. Vertical operating position only. Pollution degree 2 environment. Control circuit requires an external 24 V DC supply (19...30 V). Internal 24 V DC supply for digital inputs and STO (20.4...27 V). Internal 10.5 V DC reference for potentiometer (<10 mA). Communication via 2-wire RS-485 with Modbus RTU or BACnet MS/TP; optional communication modules for BACnet IP, PROFINET, or Ethernet IP/Modbus TCP fit the option card slot.

Frequently asked questions

What are the key safety ratings?

STO (safe torque off) rated SIL 3 per IEC 61508 and PL e per ISO 13849-1. Protection includes motor thermal overload, motor phase loss, overcurrent, short-circuit, overvoltage, undervoltage, and drive overheating.

What compliance markings does it carry?

CE, UKCA, CULus, EAC, RCM, ATEX, WEEE, ROHS, KCC. Standards include UL 61800-5-1, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, RoHS.

MPN
ATH630U30N4Z