Schneider Electric ATV1200A11506666 — AC Drive (VFD) 480V

Schneider ATV1200A11506666 Altivar 1200 MV Drive, 961 kW

MPNATV1200A11506666
Active

Schneider Electric Altivar 1200 series, ATV1200A11506666 medium voltage variable speed drive, 961 kW motor power, 36-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV1200A11506666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200
ATV1200A11506666 — Power & Output
ParameterValue
Motor power (kW)961 kW
Continuous output current100 A (standard overload) 80 A (high overload)
Max. transient current120 A for 60 s
Apparent power1150 kVA
ATV1200A11506666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current100 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)
ATV1200A11506666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)
ATV1200A11506666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms
ATV1200A11506666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows
ATV1200A11506666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)
ATV1200A11506666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1
ATV1200A11506666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

36-pulse topology and what it means for your line

The ATV1200A11506666: The 36-pulse diode rectifier bridge is the headline feature here — it cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics at the input, so the drive meets IEEE 519 without an external active filter. For a 1150 kVA apparent power rating, that saves a cabinet bay and the filter commissioning time. The phase-shifting transformer inside the enclosure creates the 36-pulse effect. The line current draw is 100 A at the 2970-3630 V supply range, so the upstream breaker and cable must be rated for medium voltage, not the 400 V class.

Physical footprint — the floor-space decision

The standard-efficiency variant measures 3360 mm wide × 1400 mm deep × 2520 mm high. The high-efficiency variant is wider at 3660 mm and deeper at 1600 mm, with height increasing to 2670 mm. That extra 300 mm width and 200 mm depth is the larger heat exchanger and higher air volume (19800 m³/h vs 16500 m³/h,). Floor-standing enclosure with separate air flows means the cooling air path is segregated from the power cell compartment — the forced convection fans pull from the room and exhaust through the top or rear. The 80 dB noise level is the fan and transformer audible output; plan for acoustic treatment if the drive is near operator stations.

Control supply and I/O architecture

The control electronics require an external 220 V AC supply at 3 kVA, separate from the main power. The cooling fans run off a separate 380 V AC supply. This split means the control cabinet can stay live for diagnostics while the main medium voltage is isolated — a commissioning and troubleshooting advantage. Four software-configurable analogue inputs accept 0-20 mA or 4-20 mA signals at 24 V max with 250 Ohm impedance. Six discrete inputs are standard, expandable to ten. The analogue output is also software-configurable for 0-20 mA or 4-20 mA. All I/O is electrically isolated from the power stage, so a ground fault on the motor side won't take out the PLC interface.

Overload capability and motor protection

Standard overload profile: 1.2 × In for 60 seconds, 1.5 × In for 3 seconds. High overload profile: 1.5 × In for 60 seconds, 1.85 × In for 3 seconds. The 961 kW motor power rating is at the drive's nominal output; the overload headroom handles starting torque and temporary load spikes on conveyors or crushers. Integrated ground fault protection monitors the motor circuit for leakage to earth. The drive also withstands a prospective line short-circuit current of 31.5 kA for 150 ms, so the upstream MV breaker must coordinate within that window. Dielectric strength is 20 kV AC between earth and power terminals, confirming the insulation class for 3.3 kV class systems.

Standards compliance and environmental limits

CE marked and designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (environmental), EN/IEC 61800-5-1 (safety), EN/IEC 60204-11 (machinery), and EN/IEC 60529 (enclosure). Pollution degree 2 per EN/IEC 61800-5-1 — suitable for clean, climate-controlled electrical rooms. Relative humidity range is 0-90 % standard, 0-95 % with the optional treatment. Operating position is vertical within ±10°. Vibration resistance is 4.9 m/s² at 10-50 Hz — adequate for floor-mounted installation in industrial buildings, but not for shipboard or seismic zones without additional anchoring.

Sourced to order against the BOM quantity through independent distribution channels.

Frequently asked questions

What is the closest alternative to ATV1200A11506666 in the Altivar 1200 family?

The ATV1200 series has multiple voltage and power variants; this specific order code defines the 961 kW, 3.3 kV class configuration with 36-pulse rectification. Any substitution would require a different enclosure size, transformer ratio, or pulse count — a full re-engineering of the installation.

What compliance documentation does Schneider provide for ATV1200A11506666?

CE marking is confirmed. The drive is designed to EN/IEC 61800-3, EN/IEC 61800-4, EN/IEC 61800-5-1, EN/IEC 60204-11, and EN/IEC 60529.

MPN
ATV1200A11506666