Skip to main content
Schneider Electric ATV1200A14504242

Schneider ATV1200A14504242 AC Drive, 1212 kW, 1450 kVA

MPN ATV1200A14504242
Active

Schneider Electric Altivar 1200 ATV1200A14504242 medium-voltage AC drive, 1212 kW motor power, 1450 kVA apparent power, 24-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A14504242 specifications
ParameterValue
Input type24 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current200 A
IP ratingIP41 / IP42 / IP31
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1400 mm (standard efficiency) 1600 mm (high efficiency)
Width4060 mm (standard efficiency) 4360 mm (high efficiency)
Height2670 mm high efficiency 2670 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Medium-voltage drive for large motor loads

The Schneider Electric ATV1200A14504242 is an Altivar 1200 series medium-voltage AC drive rated for 1212 kW motor power with 1450 kVA apparent power, designed for large induction and synchronous motors in heavy industrial applications. It accepts a supply voltage of 2970...3630 V AC through a 24-pulse diode rectifier bridge, which reduces line-side harmonics below IEEE 519 thresholds without external filters.

Overload profile and fault handling

Standard overload capability is 1.2× rated current for 60 seconds and 1.5× for 3 seconds; high overload mode extends the 1.5× window to 60 seconds and allows 1.85× for 3 seconds — this matters for crushers, conveyors, and mills that see short-duration peak torque events. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms, and dielectric strength between earth and power terminals is tested at 20 kV AC. Ground fault protection is integrated on the drive side, and the unit is pollution degree 2 rated per EN/IEC 61800-5-1.

Physical footprint and cooling

The drive ships in a floor-standing enclosure with separate air flows for power and control sections. Standard efficiency variant measures 1400 mm deep × 4060 mm wide × 2670 mm high; the high efficiency version is 1600 mm deep × 4360 mm wide at the same height. Forced convection cooling moves 16500 m³/h (standard) or 19900 m³/h (high efficiency) of air, with an 80 dB noise level — plan for hearing protection zones near the installation. Operating altitude range is 1000...2000 m with 0.6 % current derating per 100 m above 1000 m; the unit must be mounted vertically within ±10 degrees.

Compliance and lifecycle

The ATV1200A14504242 carries CE marking and conforms to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle status is current production — quoted to order against the BOM quantity through independent distribution channels.

MPN