Skip to main content
Schneider Electric ATV1200A15506666 — AC Drive (VFD) 480V

Schneider ATV1200A15506666 AC Drive, 1296 kW, 1550 kVA

MPNATV1200A15506666
Active

Schneider Electric Altivar 1200 series, ATV1200A15506666 medium-voltage AC drive, 1296 kW motor power, 1550 kVA, 2970...3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV1200A15506666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200
ATV1200A15506666 — Power & Output
ParameterValue
Motor power (kW)1296 kW
Continuous output current135 A (standard overload) 108 A (high overload)
Max. transient current162 A for 60 s
Apparent power1550 kVA
ATV1200A15506666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current135 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)
ATV1200A15506666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f) Sensorless flux vector control
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)
ATV1200A15506666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms
ATV1200A15506666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP42 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows
ATV1200A15506666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)
ATV1200A15506666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1
ATV1200A15506666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

1296 kW medium-voltage drive with 36-pulse rectifier

The ATV1200A15506666 is a medium-voltage AC drive from the Altivar 1200 series, rated for 1296 kW motor power at 1550 kVA apparent power. Supply voltage range is 2970...3630 V — this is a medium-voltage drive, not a 480 V class unit, so the input transformer and switchgear upstream need to match that voltage class. The 36-pulse diode rectifier front end means the drive presents very low line current harmonics — typically below 5 % THD without an external filter. For a 1550 kVA load, that saves the cost of a dedicated harmonic filter cabinet and simplifies IEEE 519 compliance at the point of common coupling.

The drive is assembled in a floor-standing enclosure with separate air flows for the power cells and the control section. The product composition includes 18 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and an HMI. This is a complete drive cabinet — not a modular drive that fits into a customer panel. Two efficiency variants exist: standard efficiency requires 16500 m³/h of cooling air, while the high-efficiency variant needs 19800 m³/h. The physical footprint differs between the two — standard efficiency width is 3960 mm, high efficiency width is 4260 mm; depth is 1500 mm for standard, 1600 mm for high efficiency; height is 2670 mm for both. The enclosure colour is grey RAL 7032. Forced convection cooling with a noise level of 80 dB — this is not a quiet drive; ear protection is needed in the equipment room. The operating position is vertical ±10 degrees.

Overload profiles and protection

The drive offers two overload profiles: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload handles 1.5× In for 60 s and 1.85× In for 3 s. The high overload profile is the one to specify if the motor drives a high-inertia load like a centrifuge or a crusher that needs extended torque during acceleration. Ground fault protection is built into the drive. Dielectric strength between earth and power terminals is 20 kV AC. Prospective line short-circuit current rating is 31.5 kA for 150 ms — this sets the SCCR requirement for the upstream switchgear.

I/O and control supply

The drive has 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 24 V max, 250 Ohm impedance) and 1 analogue output of the same type. Discrete inputs: 6 standard, expandable to 10. Control supply is 220 V AC at 3 kVA, with an optional 220 V AC/DC supply. The cooling fan has its own internal 380 V AC supply, with an optional external 380 V AC supply available. Electrical isolation between power and control circuits is standard for this voltage class.

CE marked. Complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1. Overvoltage category II per the same standard. Operating altitude 1000...2000 m with 0.6 % current derating per 100 m above 1000 m.

Lifecycle stage is marked as current production. The ATV1200A15506666 is sourced to order against the BOM quantity through independent distribution channels.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV1200A15506666?

The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The evidence does not list RoHS or REACH declarations specifically, but CE marking under the Low Voltage Directive implies the manufacturer's declaration of conformity covering those requirements.

MPN
ATV1200A15506666