Active production — what that means for procurement
The ATV1200A19105555: For volume BOM commitments, this drive is quoted to order against the line-item quantity.
1597 kW at medium voltage — the load it handles
Rated for 1597 kW motor power with 1910 kVA apparent power, this drive serves synchronous or asynchronous motors in the medium-voltage class. The 30-pulse diode rectifier bridge input reduces line-side harmonics compared to 6- or 12-pulse topologies — relevant for sites with strict IEEE 519 compliance requirements. Supply voltage limits are 2970...3630 V, placing it in the 3.3 kV class. The output voltage is at or below the supply voltage, so motor winding insulation must be rated for the full DC bus potential.
Overload profile and fault clearing
Standard overload withstand is 1.2 In for 60 s and 1.5 In for 3 s; the high-overload profile pushes to 1.5 In for 60 s and 1.85 In for 3 s. This matters when sizing for applications with intermittent peak loads — a crusher or centrifuge that hits 150 % torque for a few seconds will trip a drive set to standard overload if the duration exceeds 3 s. Prospective line short-circuit current is 31.5 kA for 150 ms, and dielectric strength between earth and power terminals is 20 kV AC. Ground fault protection is built into the drive. These ratings define the upstream protection coordination — the supply transformer and feeder breaker must clear within that 150 ms window.
Physical footprint and installation constraints
Assembled in a floor-standing enclosure with separate air flows. Dimensions vary by efficiency variant: standard efficiency is 1500 mm deep × 4660 mm wide × 2670 mm high; high efficiency is 1700 mm deep × 4960 mm wide × 2670 mm high. The high-efficiency variant adds 200 mm depth and 300 mm width — enough to affect floor layout and cable entry planning. Cooling is forced convection moving 23100 m³/h of air — this is substantial airflow that must be ducted or room-vented. Noise level is 80 dB, which may require hearing protection in the drive room or acoustic enclosures in noise-sensitive areas. Operating altitude range is 1000...2000 m with current derating of 0.6 % per 100 m above 1000 m. Vibration resistance is 4.9 m/s² at 10...50 Hz. The operating position is vertical ±10 degrees.
I/O complement and control supply
Four software-configurable analogue inputs accept 0...20 mA or 4...20 mA, 24 V max, 250 Ohm impedance. Two analogue outputs are similarly configurable. Discrete inputs number 6 standard, expandable to 10 optional. Control supply is external at 220 V AC, 3 kVA. The cooling fan has its own internal supply at 380 V AC, with optional external supply at 380 V AC. Electrical isolation between power and control circuits is standard — no optocoupler or DC/DC converter needed for the control interface.
CE marked. Conforms to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II per the same standard. The integrated EMC filter covers conducted emissions for the drive's rated environment. Relative humidity range is 0...90 % standard, 0...95 % optional. The product composition includes a phase-shifting transformer, medium voltage arrestors, cooling fans, a human-machine interface, and 15 power cells.