Skip to main content
Schneider Electric ATV1200A20606666 — AC Drive (VFD) 480V

Schneider Electric ATV1200A20606666 AC Drive, 1722 kW

MPNATV1200A20606666
Active

Schneider Electric Altivar 1200 ATV1200A20606666 medium-voltage AC drive, 1722 kW, 2970-3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A20606666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A20606666 — Power & Output
ParameterValue
Motor power (kW)1722 kW
Continuous output current180 A (standard overload) 144 A (high overload)
Max. transient current216 A for 60 s
Apparent power2060 kVA

Input / Supply

ATV1200A20606666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current200 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A20606666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f) Vector control with sensor, optional Sensorless flux vector control
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A20606666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A20606666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP42 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A20606666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A20606666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A20606666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive for large asynchronous motors

The Schneider Electric ATV1200A20606666 is an Altivar 1200 series medium-voltage AC drive rated for 1722 kW motor output, designed for large asynchronous motors in heavy industrial applications. It accepts a 2970 to 3630 V supply via a 36-pulse diode rectifier bridge, which inherently reduces line-side harmonics without external filters — a key advantage for plants with strict power-quality requirements. The drive is assembled in a floor-standing enclosure with separate airflows for the power section and control compartment, keeping the electronics away from the heat of the main circuit.

The 1722 kW motor power rating is the continuous output at the drive's nominal voltage range — this is the number to match against your motor nameplate, not the apparent power rating. Apparent power is 2060 kVA, and line current is 200 A at the input — these drive the sizing of upstream transformers, cables, and the main disconnect. Overload capability is defined in two profiles: standard overload allows 1.2× rated current for 60 seconds, while high overload allows 1.5× for 60 seconds — choose the profile that matches your load cycle (conveyor vs crusher). Dielectric strength is tested at 20 kV AC between earth and power terminals — this confirms the MV isolation barrier is intact for a 3.3 kV class system.

Installation and integration constraints

Physical footprint: the enclosure is 2670 mm tall, with width ranging from 5170 mm (standard efficiency) to 5470 mm (high efficiency), and depth from 1600 mm to 1700 mm — plan for a dedicated electrical room with crane access. The drive requires external control power at 220 V AC, 3 kVA, and internal cooling fans supplied at 380 V AC — these auxiliary supplies must be factored into the panel design. Operating altitude above 1000 m requires current derating at 0.6% per 100 m; at 2000 m the available output current is roughly 94% of the sea-level rating. The 36-pulse input configuration draws a line current of 200 A and is rated for a prospective short-circuit current of 31.5 kA for 150 ms — coordinate upstream protection accordingly.

CE marked and compliant with EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (thermal), and EN/IEC 61800-5-1 (safety) — covers the key standards for industrial drive installations in Europe and most global markets. Pollution degree 2 per EN/IEC 61800-5-1 means the drive is rated for a normal industrial environment with only non-conductive contamination — not for wet or conductive dust areas without additional enclosure protection.

MPN
ATV1200A20606666