Skip to main content
Schneider Electric ATV1200A22906060 — AC Drive (VFD) 480V

Schneider ATV1200A22906060 AC Drive, 1914 kW, 2290 kVA

MPNATV1200A22906060
Active

Schneider Electric Altivar 1200 ATV1200A22906060 medium-voltage AC drive, 1914 kW motor power, 2290 kVA, 30-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A22906060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A22906060 — Power & Output
ParameterValue
Motor power (kW)1914 kW
Continuous output current220 A (standard overload) 176 A (high overload)
Max. transient current264 A for 60 s
Apparent power2290 kVA

Input / Supply

ATV1200A22906060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current220 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A22906060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A22906060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A22906060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP42 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A22906060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A22906060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A22906060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive for large asynchronous and synchronous motors

The Schneider Electric ATV1200A22906060 is a medium-voltage variable frequency drive from the Altivar 1200 family, rated for 1914 kW motor power at 2290 kVA apparent power. It is designed to control both asynchronous and synchronous motors in high-power applications such as pumps, fans, compressors, and conveyors in heavy industry. The drive accepts a supply voltage of 2970–3630 V AC and draws 220 A line current through a 30-pulse diode rectifier bridge, which inherently reduces line-side harmonics to meet IEEE 519 without external filters.

Architecture and overload capability

The ATV1200A22906060 uses a modular cell-based topology: 15 power cells fed by a phase-shifting transformer, with two plinths, medium-voltage arrestors, cooling fans, and a human-machine interface. This architecture allows ride-through of individual cell faults without tripping the drive. Overload capability is configurable: standard overload allows 1.2× In for 60 s and 1.5× In for 3 s; high overload allows 1.5× In for 60 s and 1.85× In for 3 s. The 1.2× In standard overload profile suits variable-torque loads like centrifugal pumps; the 1.5× high overload profile matches constant-torque loads such as conveyors or extruders.

Physical footprint and installation constraints

The drive is supplied in a floor-standing enclosure with separate air flows for the power section and control electronics. Dimensions vary by efficiency variant: standard efficiency measures 4660 mm wide × 1600 mm deep × 2670 mm high; high efficiency is 4960 mm wide × 1700 mm deep × 2670 mm high.

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II apply to the control circuits. Dielectric strength between earth and power terminals is 20 kV AC. The integrated EMC filter covers conducted emissions for the first environment (unrestricted distribution) per EN/IEC 61800-3. Operating altitude is 1000–2000 m with a current derating of 0.6 % per 100 m above 1000 m. Ambient relative humidity range is 0–90 % (0–95 % optional). The drive is rated for vibration resistance of 4.9 m/s² at 10–50 Hz.

Frequently asked questions

Where can I buy the ATV1200A22906060 and get a price?

The drive is quoted to order against the BOM quantity.

MPN
ATV1200A22906060