Skip to main content
Schneider Electric ATV1200A22906666 — AC Drive (VFD) 480V

Schneider ATV1200A22906666 Altivar 1200 VFD, 1914 kW

MPNATV1200A22906666
Active

Schneider Electric Altivar 1200 series, ATV1200A22906666 medium-voltage AC drive, 1914 kW motor power, 2290 kVA apparent power, 200 A line current, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A22906666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A22906666 — Power & Output
ParameterValue
Motor power (kW)1914 kW
Continuous output current200 A (standard overload) 160 A (high overload)
Max. transient current240 A for 60 s
Apparent power2290 kVA

Input / Supply

ATV1200A22906666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current200 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A22906666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control Vector control with sensor, optional
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A22906666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A22906666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A22906666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A22906666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A22906666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

What this drive is and what it powers

The ATV1200A22906666 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 1914 kW motor power with 2290 kVA apparent power and 200 A line current. It's built for asynchronous motor control in applications where a standard low-voltage drive won't cut the voltage — the supply limits are 2970...3630 V AC. The 36-pulse diode rectifier input stage means the drive draws line current with low harmonic distortion — no external harmonic filter needed for most utility interfaces. The integrated EMC filter handles the conducted emissions side.

Overload capability and duty cycle

Standard overload rating: 1.2 x In for 60 seconds, 1.5 x In for 3 seconds. High overload rating pushes to 1.5 x In for 60 seconds and 1.85 x In for 3 seconds. That's the difference between a pump/fan duty and a crusher/mill duty — the high-overload window handles the breakaway torque of a loaded conveyor or a centrifuge start. The prospective line short-circuit current rating is 31.5 kA for 150 ms — the drive's input section can ride through a bolted fault on the primary side without catastrophic failure, as long as the upstream protection clears within that window.

Physical footprint and installation constraints

This is a floor-standing cabinet, not a panel-mount drive. The enclosure dimensions: 2670 mm high, 5170 mm wide (standard efficiency) or 5470 mm wide (high efficiency), and 1700 mm deep (high efficiency) or 1600 mm deep (standard efficiency). The operating position is vertical ±10 degrees — no laying it on its side. The assembly includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, an HMI, and 18 power cells. Forced convection cooling moves 23100 m³/h of air — the room's HVAC needs to handle that heat rejection, and the noise level at 80 dB means ear protection near the cabinet.

I/O complement and control wiring

Four software-configurable analogue inputs (0...20 mA / 4...20 mA, 24 V max, 250 Ohm impedance) and one analogue output of the same type. Six discrete inputs standard, expandable to ten. The control supply is 220 V AC at 3 kVA — separate from the internal fan supply at 380 V AC. Electrical isolation between power and control circuits.

Standards compliance and environmental limits

CE marked. Designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Dielectric strength tested at 20 kV AC between earth and power terminals. Operating altitude 1000...2000 m with current derating of 0.6 % per 100 m above 1000 m. Relative humidity 0...90 % standard, 0...95 % optional. Vibration resistance 4.9 m/s² at 10...50 Hz.

Frequently asked questions

What are the main electrical ratings of the ATV1200A22906666?

Motor power rating is 1914 kW, apparent power is 2290 kVA, and line current is 200 A. The input supply voltage range is 2970...3630 V AC through a 36-pulse diode rectifier. Output voltage is ≤ the supply voltage.

What overload ratings does this drive support?

Standard overload: 1.2 x In for 60 s and 1.5 x In for 3 s. High overload: 1.5 x In for 60 s and 1.85 x In for 3 s. The high-overload profile suits heavy starting duty like conveyors or mills.

What physical space does the ATV1200A22906666 require?

The floor-standing enclosure measures 2670 mm high, 5170 mm wide (standard efficiency) or 5470 mm wide (high efficiency), and 1700 mm deep (high efficiency) or 1600 mm deep (standard efficiency). Operating position is vertical ±10°.

What compliance documentation does Schneider provide for this drive?

CE marking is standard. The drive complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2, overvoltage category II. Dielectric strength tested at 20 kV AC between earth and power terminals.

MPN