Schneider Electric ATV1200A23401010 — AC Drive (VFD) 480V

Schneider ATV1200A23401010 AC Drive, 1956 kW, 2340 kVA

MPNATV1200A23401010
Active

Schneider Electric Altivar 1200 ATV1200A23401010 AC drive, 1956 kW motor power, 2340 kVA, 48-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A23401010 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A23401010 — Power & Output
ParameterValue
Motor power (kW)1956 kW
Continuous output current135 A (standard overload) 108 A (high overload)
Max. transient current162 A for 60 s
Apparent power2340 kVA

Input / Supply

ATV1200A23401010 — Input / Supply
ParameterValue
Rated supply voltage range10 kV +/- 10 %
Input line current135 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A23401010 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A23401010 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A23401010 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP41 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A23401010 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A23401010 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A23401010 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

48-pulse architecture for medium-voltage motor control

The Schneider Electric ATV1200A23401010 is a medium-voltage AC drive from the Altivar 1200 family, rated for 1956 kW motor power with 2340 kVA apparent power. Its 48-pulse diode rectifier bridge input delivers low harmonic distortion without a separate filter — a key advantage for installations where IEEE 519 compliance is a constraint. Supply voltage range is 2970–3630 V, placing it in the medium-voltage class. The output voltage is limited to or below the supply voltage, so the motor nameplate voltage must align with the available line feed.

Overload profile and thermal budget

The overload withstand table defines two duty cycles: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload pushes to 1.5× In for 60 s and 1.85× In for 3 s. This means the drive can ride through a crusher jam or a conveyor start without tripping, but the high-overload window is short — the 3 s limit at 1.85× In is a hard ceiling, not a suggestion. Forced convection cooling moves 23,100 m³/h through the floor-standing enclosure. The noise level is 80 dB — ear protection zones around the drive are expected in a typical installation.

Architecture and internal composition

The drive is built from 24 power cells fed by a phase-shifting transformer, plus medium-voltage arrestors, cooling fans, and a human-machine interface, all housed in a grey (RAL 7032) floor-standing enclosure with separate air flows for power and control sections. Electrical isolation between power and control means the control electronics can be safely referenced to earth while the power section runs at medium voltage — a standard safety separation for drives at this class. Dielectric strength is 28 kV AC between earth and power terminals, confirming the insulation coordination for a 3.3 kV class system.

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Prospective line short-circuit current withstand is 31.5 kA for 150 ms — this sets the upstream fuse or breaker requirement for coordination. The integrated EMC filter covers conducted emissions for the first environment per EN/IEC 61800-3.

Sourcing and lifecycle position

Sourced through independent distribution channels. For a drive of this scale — 1956 kW, floor-standing, 24 power cells — the quote should include the full enclosure dimensions (1700 mm depth, 5160 mm width, 2670 mm height) for site access planning.

Frequently asked questions

What compliance documentation does Schneider provide for this drive?

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The datasheet and declaration of conformity are available from Schneider Electric.