Specifications

Identification

ATV1200A25006060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A25006060 — Power & Output
ParameterValue
Motor power (kW)2090 kW
Continuous output current241 A (standard overload) 192 A (high overload)
Max. transient current289 A for 60 s
Apparent power2500 kVA

Input / Supply

ATV1200A25006060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current280 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A25006060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Vector control with sensor, optional Closed-loop control with encoder Voltage/frequency ratio (V/f)
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A25006060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A25006060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP42 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A25006060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A25006060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A25006060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

The ATV1200A25006060 is a Schneider Electric Altivar 1200 medium-voltage variable speed drive rated for 2090 kW motor power at a supply voltage of 2970 to 3630 V. That 2090 kW figure is the continuous motor output the drive can support under standard overload conditions — not a peak or short-time rating. The input stage uses a 30-pulse diode rectifier bridge, which means the harmonic distortion fed back to the line is significantly lower than a 6- or 12-pulse design — relevant if your facility has a utility-imposed harmonic limit or you're feeding from a weak grid. Overload capability is specified as 1.2 In for 60 seconds (standard overload) and 1.5 In for 3 seconds, with a high-overload profile at 1.5 In for 60 seconds and 1.85 In for 3 seconds. The 60-second window at 1.2× rated current covers most starting and load-transient scenarios without forcing a larger drive frame.

Physical footprint and enclosure integration

This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 4660 mm wide by 1600 mm deep by 2670 mm high; the high-efficiency variant is 4960 mm wide by 1700 mm deep at the same height. Forced convection cooling moves 23100 m³/h of air through the cabinet — that volume has to be accounted for in the room's HVAC design, especially if the drive sits in a confined electrical room with other heat sources. The enclosure colour is grey RAL 7032, and the operating position is vertical within ±10 degrees. Mounting orientation outside that window will affect the cooling airflow path and may require derating.

Supply requirements and auxiliary power

The main power supply range is 2970 to 3630 V, with a prospective line short-circuit current withstand of 31.5 kA for 150 ms. That fault rating tells you the drive's input bus can survive a bolted fault at the line terminals long enough for upstream protection to clear — coordination with the supply-side breaker is still required. Control power comes from an external 220 V AC, 3 kVA supply. The cooling fans draw from an internal 380 V AC supply, with an optional external 220 V AC/DC control supply and external 380 V AC fan supply listed as alternatives. The 3 kVA control transformer must be sized into the panel's auxiliary load budget. Line current at rated load is 280 A, with an apparent power of 2500 kVA. The power connection uses M10 bar-type screw terminals accepting 6 x 40 mm² conductors per phase, entry from the bottom or top.

I/O complement and control interface

The drive provides 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ohm impedance) and 1 analogue output of the same type. Discrete inputs number 6 standard, expandable to 10 via an optional module. Electrical isolation is maintained between the power and control circuits — the dielectric strength between earth and power terminals is tested at 20 kV AC. This isolation rating is consistent with the EN/IEC 61800-5-1 standard for medium-voltage drives and supports direct connection to the motor without an intermediate isolation transformer in most configurations.

Environmental limits and derating rules

Operating altitude from 1000 to 2000 m requires a current derating of 0.6 % per 100 m above 1000 m. At 2000 m, that's a 6 % reduction in available output current — factor this into the motor sizing if the installation is at elevation. Relative humidity range is 0 to 90 % non-condensing, with an optional extension to 95 %. Pollution degree 2 per EN/IEC 61800-5-1 applies, meaning only non-conductive pollution is expected — the enclosure seal and filter maintenance schedule should reflect the actual site conditions. Vibration resistance is 4.9 m/s² over 10 to 50 Hz, and the noise level at full load is 80 dB. The 80 dB figure is the acoustic emission at the operator position — hearing protection may be required in the drive room depending on local noise exposure limits.

Compliance and standards coverage

CE marked and designed to EN/IEC 60204-11 (electrical equipment of machines — requirements for HV equipment), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for adjustable-speed drives), EN/IEC 61800-4 (general requirements for LV and MV drives), and EN/IEC 61800-5-1 (electrical, thermal, and energy safety). An integrated EMC filter is included, and overvoltage category II per EN/IEC 61800-5-1 applies. The drive supports both synchronous and asynchronous motors per the product destination listing.

Lifecycle status and sourcing posture

The product composition includes 2 plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 15 power cells. Each power cell is a modular building block — if a cell fails in service, the drive can continue at reduced capacity while the replacement cell is sourced. Sourced to order against the BOM quantity through independent industrial distribution.

Frequently asked questions

What motor types does ATV1200A25006060 support?

The drive is designed for both synchronous and asynchronous motors. The 2090 kW rating applies to continuous motor output under standard overload conditions.

What compliance documentation does Schneider provide for ATV1200A25006060?

The drive is CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter is included.

How is ATV1200A25006060 quoted for volume purchases?

Sourced to order against the BOM quantity through independent industrial distribution.

MPN