Skip to main content
Schneider Electric ATV1200A29106060 — AC Drive (VFD) 480V

Schneider Electric ATV1200A29106060 Altivar 1200, 2433 kW

MPNATV1200A29106060
Active

Schneider Electric Altivar 1200 series, ATV1200A29106060, medium-voltage variable speed drive, 2433 kW motor power, 2910 kVA apparent power, 30-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A29106060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A29106060 — Power & Output
ParameterValue
Motor power (kW)2433 kW
Continuous output current280 A (standard overload) 224 A (high overload)
Max. transient current336 A for 60 s
Apparent power2910 kVA

Input / Supply

ATV1200A29106060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current280 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A29106060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A29106060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A29106060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A29106060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A29106060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A29106060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

What it takes to drive a 2.4 MW motor

The ATV1200A29106060 is a medium-voltage drive from the Altivar 1200 family, rated for 2433 kW motor power at an apparent power of 2910 kVA. It accepts a supply voltage between 2970 and 3630 V and uses a 30-pulse diode rectifier bridge on the input — that pulse count keeps line-side harmonics low enough to avoid a separate filter in most installations.

The drive supports two overload profiles: standard overload handles 1.2 × In for 60 seconds and 1.5 × In for 3 seconds; high overload handles 1.5 × In for 60 seconds and 1.85 × In for 3 seconds. Pick the standard profile for centrifugal loads (pumps, fans) where the overload event is short; go with the high-overload curve for extruders, crushers, or conveyors that need a longer torque punch during start-up or jam recovery.

Physical footprint and installation constraints

This is a floor-standing enclosure with separate air flows for power and control sections. Standard-efficiency build measures 4660 mm wide × 2820 mm high × 1600 mm deep; the high-efficiency variant is wider (4960 mm) and deeper (1700 mm). Plan for a 43200 m³/h cooling air volume — that is forced convection, so the room ventilation and ducting must handle that flow without back-pressure on the fan intakes.

Line fault handling and altitude derating

The drive is rated for a prospective line short-circuit current (Isc) of 31.5 kA for 150 ms — that is the fault level the input section can withstand without damage. Above 1000 m operating altitude, derate the output current by 0.6 % per 100 m up to 2000 m. The dielectric strength between earth and power terminals is 20 kV AC, and pollution degree 2 per EN/IEC 61800-5-1 applies, so the enclosure is suited for clean industrial environments.

Standards and compliance package

CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The integrated EMC filter covers conducted emissions for the drive's power range. Electrical isolation between power and control circuits is standard. The enclosure colour is grey RAL 7032.

Frequently asked questions

How do I get current pricing and availability for ATV1200A29106060?

Submit an RFQ with your target quantity and delivery window.

What compliance documentation does this brand provide for ATV1200A29106060 (RoHS, REACH, UL, IEC)?

The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The evidence does not list RoHS, REACH, or UL specifically for this order code.

MPN
ATV1200A29106060