Skip to main content
Schneider Electric ATV1200A30506363 — AC Drive (VFD) 480V

Schneider Electric ATV1200A30506363 AC Drive, 2232 kW, 3 kV

MPNATV1200A30506363
Active

Schneider Electric Altivar 1200 series, ATV1200A30506363 medium-voltage AC drive, 2232 kW motor power, 2970…3630 V supply, 36-pulse rectifier, floor-standing enclosure.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A30506363 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A30506363 — Power & Output
ParameterValue
Motor power (kW)2232 kW
Continuous output current245 A (standard overload) 196 A (high overload)
Max. transient current294 A for 60 s
Apparent power2670 kVA

Input / Supply

ATV1200A30506363 — Input / Supply
ParameterValue
Rated supply voltage range6.3 kV +/- 10 %
Input line current280 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A30506363 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A30506363 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A30506363 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A30506363 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A30506363 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A30506363 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive for large synchronous and asynchronous motors

The ATV1200A30506363 is a 2232 kW medium-voltage AC drive from the Altivar 1200 family, designed for large motor loads in the 3 kV class. It accepts a 2970…3630 V supply via a 36-pulse diode rectifier bridge, which reduces line-side harmonics below the thresholds that typically require external filters. It drives both synchronous and asynchronous motors, making it suitable for pumps, compressors, conveyors, and fans in heavy industries such as mining, cement, and water treatment.

Overload capability and duty-cycle fit

Standard overload rating: 1.2 × In for 60 seconds and 1.5 × In for 3 seconds. High overload rating: 1.5 × In for 60 seconds and 1.85 × In for 3 seconds. This means the drive handles short-duration peak torque demands during motor starting or process upsets without tripping.

Physical footprint and installation constraints

The drive ships in a floor-standing enclosure with separate air flows for the transformer and power cells. Standard-efficiency width is 5170 mm; high-efficiency width is 5470 mm. Depth is 1700 mm for both variants, and height is 2740 mm. The assembly includes the phase-shifting transformer, 18 power cells, cooling fans, and an HMI. Forced convection cooling requires 43,200 m³/h of air flow — plan the drive room HVAC capacity accordingly. The drive produces 80 dB acoustic noise at full load, so hearing protection zones near the enclosure are expected.

Standards compliance and insulation coordination

CE marked and conforms to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (thermal), EN/IEC 61800-5-1 (safety), EN/IEC 60204-11 (machinery), and EN/IEC 60529 (enclosure protection). Pollution degree 2, overvoltage category II per EN/IEC 61800-5-1. Dielectric strength is 20 kV AC between earth and power terminals. Electrical isolation between power and control circuits is maintained. The integrated EMC filter covers conducted emissions for the 3 kV class without external add-ons.

Frequently asked questions

What compliance documentation does Schneider Electric provide for the ATV1200A30506363?

The drive carries CE marking and conforms to EN/IEC 61800-3, EN/IEC 61800-4, EN/IEC 61800-5-1, EN/IEC 60204-11, and EN/IEC 60529. A declaration of conformity is available from the manufacturer.

MPN
ATV1200A30506363