Schneider Electric ATV1200A31306060 — AC Drive (VFD) 480V

Schneider ATV1200A31306060 AC Drive, 2617 kW, 3130 kVA

MPNATV1200A31306060
Active

Schneider Electric Altivar 1200 ATV1200A31306060 medium-voltage AC drive, 2617 kW motor power, 3130 kVA apparent power, 30-pulse diode rectifier, 2970...3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A31306060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A31306060 — Power & Output
ParameterValue
Motor power (kW)2617 kW
Continuous output current301 A (standard overload) 241 A (high overload)
Max. transient current361 A for 60 s
Apparent power3130 kVA

Input / Supply

ATV1200A31306060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current320 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A31306060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Sensorless flux vector control Closed-loop control with encoder Vector control with sensor, optional
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A31306060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A31306060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP41 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A31306060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A31306060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A31306060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

What the 30-pulse input and 3.3 kV rail mean for the installation

The ATV1200A31306060: The 30-pulse diode rectifier bridge is the key harmonic-mitigation feature — it effectively cancels the 5th, 7th, 11th, and 13th harmonics at the input, so the drive meets IEEE 519 without a separate filter bank. The supply voltage limits are 2970...3630 V, which covers the nominal 3.3 kV class with margin for typical utility swings. At 3130 kVA apparent power and 2617 kW motor power, this is a medium-voltage drive sized for large induction or synchronous motors — think mainline conveyors, mill drives, or large pumps in mining and water.

Overload profile and fault-withstand capability

Standard overload rating is 1.2 × In for 60 s and 1.5 × In for 3 s; the high-overload profile pushes to 1.5 × In for 60 s and 1.85 × In for 3 s. That high-overload envelope suits applications with heavy starting duty or short-duration peak loads — crushers, extruders, or centrifuge starts. The prospective line short-circuit current is 31.5 kA for 150 ms, which means the drive's input section can ride through a fault on the primary distribution bus without collapsing the DC bus or damaging the rectifier bridge. Dielectric strength between earth and power terminals is 20 kV AC — a safety margin that reflects the medium-voltage isolation requirements.

Physical footprint and cooling — what ships in the enclosure

The drive ships as a floor-standing enclosure with separate air flows for the power cells and the transformer section. Standard-efficiency configuration: 5770 mm wide × 2670 mm high × 1600 mm deep; high-efficiency variant adds width to 6070 mm and depth to 1700 mm. The product composition includes the phase-shifting transformer, 15 power cells, medium-voltage arrestors, cooling fans, and the HMI. Cooling is forced convection at 29,700 m³/h for both efficiency grades. Noise level is 80 dB — plan for hearing protection zones around the drive room.

Compliance and standards package

CE marked. Designed to EN/IEC 61800-3 (EMC environment), EN/IEC 61800-4 (voltage sag immunity), EN/IEC 61800-5-1 (electrical safety), EN/IEC 60204-11 (semiconductor converter equipment), and EN/IEC 60529 (enclosure ingress protection). Pollution degree 2 per EN/IEC 61800-5-1. Overvoltage category II. The integrated EMC filter covers conducted emissions for the drive's rated power — no external filter needed for most industrial installations.

Frequently asked questions

What compliance documentation ships with the ATV1200A31306060?

The drive is CE marked and designed to EN/IEC 61800-3, 61800-4, 61800-5-1, 60204-11, and 60529. The integrated EMC filter covers conducted emissions. Documentation includes the EC Declaration of Conformity and the product manual covering installation, commissioning, and maintenance.