Skip to main content
Schneider Electric ATV1200A40004242 — AC Drive (VFD) 480V

Schneider Electric ATV1200A40004242 Altivar 1200, 3344 kW

MPNATV1200A40004242
Active

Schneider Electric Altivar 1200 series, ATV1200A40004242 medium-voltage variable speed drive, 3344 kW motor power, 2970-3630 V supply, 24-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A40004242 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A40004242 — Power & Output
ParameterValue
Motor power (kW)3344 kW
Continuous output current550 A (standard overload) 440 A (high overload)
Max. transient current660 A for 60 s
Apparent power4000 kVA

Input / Supply

ATV1200A40004242 — Input / Supply
ParameterValue
Rated supply voltage range4.16 kV +/- 10 %
Input line current550 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A40004242 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Sensorless flux vector control Vector control with sensor, optional Voltage/frequency ratio (V/f)
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A40004242 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A40004242 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A40004242 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A40004242 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A40004242 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive for 3.3 kV motors — 24-pulse rectifier, 3344 kW

The ATV1200A40004242 is a Schneider Electric Altivar 1200 medium-voltage variable speed drive rated for 3344 kW motor power at a supply voltage of 2970...3630 V AC. Its 24-pulse diode rectifier bridge input topology draws line current of 550 A and presents an apparent power of 4000 kVA, with a prospective line short-circuit current withstand of 31.5 kA for 150 ms. This drive is designed for asynchronous and synchronous motors in applications requiring a speed range of 20...100%.

Physical footprint and installation constraints

The drive is assembled in a floor-standing enclosure with separate air flows for power and control sections. External dimensions are 1800 mm depth, 6670 mm width, and 2740 mm height at standard efficiency. Forced convection cooling moves 70000 m³/h of air. The operating position is vertical within ±10 degrees. Operating altitude is 1000...2000 m with a current derating of 0.6% per 100 m above 1000 m. Electrical connection uses M10 screw-type bars with clamping capacity for 6 x 40 mm² cables on the line side (/R, L2/S, L3/T), entry from bottom or top.

Overload capability and protection envelope

Standard overload profile: 1.2 × In for 60 seconds, 1.5 × In for 3 seconds. High overload profile: 1.5 × In for 60 seconds, 1.85 × In for 3 seconds. Ground fault protection is integrated at the drive level. Dielectric strength between earth and power terminals is 20 kV AC. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. The drive includes an integrated EMC filter and meets EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. CE marked.

Control interface and I/O complement

Four software-configurable analogue inputs accept 0...20 mA or 4...20 mA, 24 V max, 250 Ω impedance. One analogue output is similarly configurable for 0...20 mA or 4...20 mA DC, 250 Ω impedance. Six discrete inputs are standard, expandable to ten. Electrical isolation is maintained between power and control circuits. The product composition includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and twelve power cells.

Frequently asked questions

How do I get current pricing and availability for ATV1200A40004242?

Submit an RFQ for this order code.

MPN
ATV1200A40004242