Schneider Electric ATV1200A5606666

Schneider ATV1200A5606666 AC Drive, 468 kW, 560 kVA

MPN ATV1200A5606666
Active

Schneider Electric Altivar 1200 series, ATV1200A5606666 medium-voltage AC drive, 468 kW motor power, 560 kVA apparent power, 2970…3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A5606666 specifications
ParameterValue
Input type36 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current65 A
IP ratingIP41 / IP31 / IP42
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1400 mm (standard efficiency) 1500 mm (high efficiency)
Width3360 mm (high efficiency) 3060 mm (standard efficiency)
Height2520 mm standard efficiency 2670 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Medium-voltage drive for 468 kW asynchronous motor loads

The Schneider Electric ATV1200A5606666 is an Altivar 1200 series medium-voltage AC drive rated for 468 kW motor power at 560 kVA apparent power, supplied from a 2970…3630 V line via a 36-pulse diode rectifier bridge. That multi-pulse input topology keeps line-side harmonics low enough to meet IEEE 519 without a separate filter in most installations — a real advantage when the site's utility imposes strict THD limits. The drive is built for asynchronous (induction) motors and ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 3060 mm wide × 2520 mm high × 1400 mm deep; the high-efficiency variant is slightly larger at 3360 mm wide × 2670 mm high × 1500 mm deep. Either way, the footprint demands a dedicated equipment room with a reinforced floor and a ventilation plan that moves 13,200–16,500 m³/h of cooling air.

Overload profile and fault-current rating

The overload withstand is specified for both standard and high-overload duty cycles: 1.2 × In for 60 s or 1.5 × In for 3 s under standard overload, and 1.5 × In for 60 s or 1.85 × In for 3 s under high overload. That means the drive can handle a 185 % current spike for three seconds — enough to start a loaded conveyor or crusher without tripping on the inrush. The prospective short-circuit current rating is 31.5 kA for 150 ms, which tells the site electrical engineer that the upstream protection (fuses or breaker) must be coordinated to clear within that window. The line current draw is 65 A at the rated operating point. Electrical connection is via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, with entry from the top or bottom of the enclosure. That gives the panel builder flexibility in cable routing, but the lug size and bending radius need to be checked against the actual cable spec.

Compliance and documentation for global projects

The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle status is current production. The paperwork — CE declaration, IEC compliance statements — is available with the shipment.