Skip to main content
Schneider Electric ATV1200A5606666 — AC Drive (VFD) 480V

Schneider ATV1200A5606666 AC Drive, 468 kW, 560 kVA

MPNATV1200A5606666
Active

Schneider Electric Altivar 1200 series, ATV1200A5606666 medium-voltage AC drive, 468 kW motor power, 560 kVA apparent power, 2970…3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A5606666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A5606666 — Power & Output
ParameterValue
Motor power (kW)468 kW
Continuous output current49 A (standard overload) 39 A (high overload)
Max. transient current59 A for 60 s
Apparent power560 kVA

Input / Supply

ATV1200A5606666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current65 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A5606666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVector control with sensor, optional Voltage/frequency ratio (V/f) Closed-loop control with encoder Sensorless flux vector control
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A5606666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A5606666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP31 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A5606666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A5606666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A5606666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive for 468 kW asynchronous motor loads

The Schneider Electric ATV1200A5606666 is an Altivar 1200 series medium-voltage AC drive rated for 468 kW motor power at 560 kVA apparent power, supplied from a 2970…3630 V line via a 36-pulse diode rectifier bridge. That multi-pulse input topology keeps line-side harmonics low enough to meet IEEE 519 without a separate filter in most installations — a real advantage when the site's utility imposes strict THD limits. The drive is built for asynchronous (induction) motors and ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 3060 mm wide × 2520 mm high × 1400 mm deep; the high-efficiency variant is slightly larger at 3360 mm wide × 2670 mm high × 1500 mm deep. Either way, the footprint demands a dedicated equipment room with a reinforced floor and a ventilation plan that moves 13,200–16,500 m³/h of cooling air.

Overload profile and fault-current rating

The overload withstand is specified for both standard and high-overload duty cycles: 1.2 × In for 60 s or 1.5 × In for 3 s under standard overload, and 1.5 × In for 60 s or 1.85 × In for 3 s under high overload. That means the drive can handle a 185 % current spike for three seconds — enough to start a loaded conveyor or crusher without tripping on the inrush. The prospective short-circuit current rating is 31.5 kA for 150 ms, which tells the site electrical engineer that the upstream protection (fuses or breaker) must be coordinated to clear within that window. The line current draw is 65 A at the rated operating point. Electrical connection is via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, with entry from the top or bottom of the enclosure. That gives the panel builder flexibility in cable routing, but the lug size and bending radius need to be checked against the actual cable spec.

Compliance and documentation for global projects

The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle status is current production. The paperwork — CE declaration, IEC compliance statements — is available with the shipment.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV1200A5606666?

The drive is CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The CE declaration and IEC compliance statements are provided with the unit.

How is ATV1200A5606666 quoted for volume purchases?

The drive is sourced to order against the BOM quantity through authorized distribution.

MPN
ATV1200A5606666