Skip to main content
Schneider Electric ATV1200A5703333 — AC Drive (VFD) 480V

Schneider Electric ATV1200A5703333 Altivar 1200 VFD, 570 kVA

MPNATV1200A5703333
Active

Schneider Electric Altivar 1200 series, ATV1200A5703333 medium-voltage AC drive, 570 kVA, 477 kW, 18-pulse rectifier, floor-standing enclosure.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A5703333 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A5703333 — Power & Output
ParameterValue
Motor power (kW)477 kW
Continuous output current100 A (standard overload) 80 A (high overload)
Max. transient current120 A for 60 s
Apparent power570 kVA

Input / Supply

ATV1200A5703333 — Input / Supply
ParameterValue
Rated supply voltage range3.3 kV +/- 10 %
Input line current100 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A5703333 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f)
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A5703333 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A5703333 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A5703333 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A5703333 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A5703333 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Physical footprint and enclosure

The ATV1200A5703333: This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment. The standard-efficiency variant measures 1400 mm deep by 2460 mm wide by 2520 mm high; the high-efficiency variant adds depth to 1500 mm, width to 2760 mm, and height to 2670 mm. Forced-convection cooling moves 9900 m³/h (standard efficiency) or 13200 m³/h (high efficiency) of air. The 80 dB noise level means the enclosure location needs an acoustic assessment if it sits near occupied areas.

Power section and input topology

The input stage uses an 18-pulse diode rectifier bridge, which reduces line-side harmonics below the limits of IEEE 519 without an external filter. Supply voltage limits are 2970 to 3630 V AC, drawing 100 A line current at full load. Apparent power rating is 570 kVA, with a motor power capability of 477 kW for both asynchronous and synchronous motors. Output voltage equals the supply voltage, so the motor winding insulation must match the incoming line level. The drive withstands a prospective short-circuit current of 31.5 kA for 150 ms — coordinate the upstream protection to clear within that window to avoid damage to the input bridge.

Overload capability and motor protection

Standard overload profile handles 1.2 × In for 60 seconds and 1.5 × In for 3 seconds. The high-overload profile extends to 1.5 × In for 60 seconds and 1.85 × In for 3 seconds — this matters when sizing for high-inertia loads like centrifuges or crushers that need breakaway torque. Ground-fault protection is built into the drive, covering the power section. Dielectric strength between earth and power terminals is 10 kV AC.

Control wiring and auxiliaries

The control section needs an external 220 V AC supply rated at 3 kVA; an optional 220 V AC/DC supply is available. The cooling fan runs on a separate 380 V AC supply, also optional. Electrical isolation between power and control circuits is standard. Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and one analogue output of the same type handle process feedback. Six discrete inputs are standard, expandable to ten with an option card.

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (safety). Pollution degree 2 per the safety standard and overvoltage category II apply. An integrated EMC filter is fitted as standard. Operating altitude is 1000 to 2000 m with a derating of 0.6 % per 100 m above 1000 m — factor this into the installation if the site is above 1000 m elevation.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV1200A5703333?

The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1.

MPN