Schneider Electric ATV1200A57206060 — AC Drive (VFD) 480V

Schneider Electric ATV1200A57206060 AC Drive, 4782 kW

MPNATV1200A57206060
Active

Schneider Electric Altivar 1200 ATV1200A57206060 medium-voltage AC drive, 4782 kW motor power, 2970-3630 V supply, 30-pulse rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A57206060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A57206060 — Power & Output
ParameterValue
Motor power (kW)4782 kW
Continuous output current550 A (standard overload) 440 A (high overload)
Max. transient current661 A for 60 s
Apparent power5720 kVA

Input / Supply

ATV1200A57206060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current550 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A57206060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f) Sensorless flux vector control
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A57206060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A57206060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP31 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A57206060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A57206060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A57206060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

What a 4.8 MW drive means on the mill floor

The ATV1200A57206060 is a medium-voltage AC drive rated for 4782 kW motor power, supplied from a 2970–3630 V line through a 30-pulse diode rectifier bridge. That 30-pulse front end keeps input harmonics low enough to skip a dedicated harmonic filter on most mill buses — the transformer secondary windings handle the phase shifting. The drive is designed for synchronous and asynchronous motors, so it covers both the main mill stand drives and the larger wound-rotor or PM motors in the line. Overload capability is specified in four bands: 1.2 × In for 60 s and 1.5 × In for 3 s under standard overload, plus 1.5 × In for 60 s and 1.85 × In for 3 s under high overload. On a hot-strip mill where the cobble catch can spike the torque demand for a few seconds, the 1.85 × In / 3 s window is the one that keeps the drive from tripping on a transient overload that the upstream breaker would see as a fault.

Physical footprint and integration constraints

The drive ships as a floor-standing enclosure with separate air flows for the power cells and the control section. Overall dimensions are 3040 mm high × 7770 mm wide × 1800 mm deep. That width is the limiting dimension for most plant-floor layouts — you need a bay wide enough to swing the doors fully open for cell access. The enclosure colour is grey RAL 7032. Cooling is forced convection, moving 80,000 m³/h of air at standard efficiency. That volume drives the HVAC and ducting design — the room's air-handling system must supply clean, filtered air at that rate, or the drive derates. Operating altitude is 1000–2000 m with a 0.6 % current derating per 100 m above 1000 m. Noise level at full load is 80 dB. Power connections are bar-type terminals, M10 screws, clamping capacity 6 × 40 mm² per phase, with cable entry from the bottom or top. The input line prospective short-circuit current rating is 31.5 kA for 150 ms — this sets the upstream breaker's let-through requirement for fault coordination.

Standards, isolation, and environmental ratings

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (safety). Electrical isolation is maintained between power and control circuits. The integrated EMC filter covers the conducted emission limits for the second environment (industrial) per EN/IEC 61800-3. Pollution degree is 2 per EN/IEC 61800-5-1, overvoltage category II. Dielectric strength between earth and power terminals is 20 kV AC. Operating position is vertical ±10°, relative humidity 0–90 % (0–95 % optional). Vibration resistance is 4.9 m/s² from 10–50 Hz.

Control I/O and auxiliary supplies

The drive includes 4 software-configurable analogue inputs (0–20 mA / 4–20 mA, 24 V max, 250 Ω impedance) and 2 analogue outputs (same current ranges, 250 Ω). Discrete inputs are 6 standard, expandable to 10. The control section requires an external 220 V AC supply at 3 kVA; the cooling fans run on 380 V AC. An optional external 220 V AC/DC control supply is available. The product composition includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 15 power cells. The HMI is the primary commissioning interface — all I/O mapping, motor data entry, and parameter tuning happen through it.

Frequently asked questions

How can I order ATV1200A57206060 or check availability?

This drive is quoted to order against the BOM quantity. Submit an RFQ with your target quantity and delivery window.

What are the key electrical ratings of ATV1200A57206060?

Motor power is 4782 kW, supply voltage range is 2970–3630 V, input type is a 30-pulse diode rectifier, line current is 550 A, and apparent power is 5720 kVA. Overload capability includes 1.85 × In for 3 s under high overload.

MPN
ATV1200A57206060