Specifications

Identification

ATV1200A6101010 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A6101010 — Power & Output
ParameterValue
Motor power (kW)510 kW
Continuous output current35 A (standard overload) 28 A (high overload)
Max. transient current42 A for 60 s
Apparent power610 kVA

Input / Supply

ATV1200A6101010 — Input / Supply
ParameterValue
Rated supply voltage range10 kV +/- 10 %
Input line current35 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A6101010 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control Vector control with sensor, optional
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A6101010 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A6101010 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A6101010 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A6101010 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A6101010 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Active production — what that means for your BOM line

The ATV1200A6101010: For a 510 kW medium-voltage drive at this power level, lead time and pricing depend on the BOM quantity and delivery window. Quoted to order against the project schedule; availability confirmed at RFQ.

510 kW / 610 kVA — sizing the drive to the motor load

Rated 510 kW motor power with 610 kVA apparent power at the output. The 48-pulse diode rectifier input keeps line-side harmonics low enough to meet IEEE 519 without a separate filter in most installations — the phase-shifting transformer in the cabinet handles the cancellation. Supply voltage range is 2970–3630 V — this is a medium-voltage drive, not a 480 V unit. The output voltage tracks the supply, so motor nameplate voltage must match the available line. Standard overload: 1.2 In for 60 s, 1.5 In for 3 s. High overload profile: 1.5 In for 60 s, 1.85 In for 3 s. Coordinate the upstream breaker's instantaneous trip setting to stay above this threshold.

Floor-standing cabinet — physical footprint and site prep

Cooling is forced convection with 19,800 m³/h airflow at standard efficiency. The internal cooling fan runs on 380 V AC; the control supply is 220 V AC, 3 kVA. Noise level is 80 dB — hearing protection zones around the drive are standard. Electrical connection uses M10 bar-type terminals with clamping capacity for 6 × 40 mm² conductors per phase, entry from bottom or top. The cabinet includes 2 plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, an HMI, and 24 power cells.

Compliance and approvals — what ships with the drive

CE marked. Designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Integrated EMC filter — the drive meets the conducted emission limits of the 61800-3 standard for the intended environment. Dielectric strength tested at 28 kV AC between earth and power terminals. Electrical isolation between power and control sections. Operating altitude 1000–2000 m with 0.6 % current derating per 100 m above 1000 m.

Frequently asked questions

What is the motor power rating of the ATV1200A6101010?

Rated for 510 kW motor power with 610 kVA apparent power. The supply voltage range is 2970–3630 V, making this a medium-voltage drive — not a 480 V unit.

What compliance documentation does Schneider provide for the ATV1200A6101010?

CE marked. Complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2, overvoltage category II. Integrated EMC filter.