Skip to main content
Schneider Electric ATV1200A63006666

Schneider ATV1200A63006666 AC Drive, 5267 kW, 6300 kVA

MPN ATV1200A63006666
Active

Schneider Electric Altivar 1200 series, ATV1200A63006666 medium-voltage AC drive, 5267 kW motor power, 6300 kVA apparent power, 36-pulse diode rectifier input, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A63006666 specifications
ParameterValue
Input type36 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current550 A
IP ratingIP31 / IP42 / IP41
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1800 mm (standard efficiency)
Width8570 mm (standard efficiency)
Height3040 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

5267 kW medium-voltage drive with 36-pulse input

The Schneider Electric ATV1200A63006666 is a medium-voltage AC drive from the Altivar 1200 series, rated for 5267 kW motor power with 6300 kVA apparent power. The 36-pulse diode rectifier bridge input significantly reduces line harmonics compared to 6- or 12-pulse topologies, often eliminating the need for external harmonic filters in utility compliance studies. Supply voltage range is 2970...3630 V, placing it squarely in the 3.3 kV medium-voltage class. Output voltage tracks the supply voltage, so the motor sees the same voltage class as the input — no step-down transformer needed between drive and motor for a 3.3 kV machine.

Physical footprint and cooling infrastructure

Cooling is forced convection moving 90000 m³/h of air — the facility HVAC must handle this heat rejection, and the air intake/exhaust louvres need to be sized for the full airflow without backpressure. Noise level is 80 dB, so hearing protection zones and acoustic treatment are part of the site plan.

Overload capability and duty cycle

The drive offers two overload profiles. Standard overload: 1.2× rated current for 60 seconds or 1.5× for 3 seconds. High overload: 1.5× for 60 seconds or 1.85× for 3 seconds. For a 5267 kW motor driving a high-inertia load like a centrifuge or ball mill, the high-overload profile provides the starting torque margin without oversizing the drive frame. Speed range is 20...100%, meaning the drive delivers full torque down to 20% base speed — adequate for most pump, fan, and compressor applications. Below 20% speed, additional cooling or a separate blower motor may be needed for the driven motor.

Product composition and modular architecture

The ATV1200A63006666 consists of 18 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and two plinths. The modular cell topology means a single failed power cell can be replaced without decommissioning the entire drive — the remaining 17 cells continue running at reduced capacity until the replacement arrives. Electrical connection is via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom. This allows both top-entry cable trays and bottom-entry trench routing — the site electrical contractor needs to coordinate the cable entry direction before the enclosure is set in place.

Standards, approvals, and environmental limits

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. These cover electrical equipment safety, enclosure protection, EMC emissions/immunity, and adjustable-speed drive performance — sufficient for European CE-marked installations and accepted in most global markets under mutual recognition. Operating altitude is 1000...2000 m with 0.6% current derating per 100 m above 1000 m. At 2000 m elevation, derate continuous current by 6%. Pollution degree 2 per EN/IEC 61800-5-1 means the drive is suitable for clean industrial environments with only non-conductive dust — not for outdoor or heavy-contamination sites without additional enclosure protection. Lifecycle status is current production.

MPN