Skip to main content
Schneider Electric ATV1200A63506060 — AC Drive (VFD) 480V

Schneider ATV1200A63506060 AC Drive, 5309 kW, 6350 kVA

MPNATV1200A63506060
Active

Schneider Electric Altivar 1200 ATV1200A63506060 medium-voltage AC drive, 5309 kW motor power, 6350 kVA apparent power, 2970-3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A63506060 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A63506060 — Power & Output
ParameterValue
Motor power (kW)5309 kW
Continuous output current611 A (standard overload) 489 A (high overload)
Max. transient current733 A for 60 s
Apparent power6350 kVA

Input / Supply

ATV1200A63506060 — Input / Supply
ParameterValue
Rated supply voltage range6 kV +/- 10 %
Input line current720 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A63506060 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Closed-loop control with encoder Voltage/frequency ratio (V/f) Vector control with sensor, optional
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A63506060 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A63506060 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP42 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A63506060 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A63506060 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A63506060 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

5309 kW medium-voltage VFD in a floor-standing cabinet

The ATV1200A63506060 is a medium-voltage AC drive from the Altivar 1200 series, rated for 5309 kW motor power at 6350 kVA apparent power. It accepts a supply voltage of 2970 to 3630 V AC and delivers output voltage up to the supply level. This is a large-format drive assembled in a floor-standing enclosure with separate airflows for the power section and control electronics. The cabinet footprint is substantial: 7770 mm wide, 3040 mm high, and 1800 mm deep.

30-pulse input and overload curves

The input stage uses a 30-pulse diode rectifier bridge, which significantly reduces line-side harmonics compared to 6- or 12-pulse designs. Prospective line fault current is rated at 31.5 kA for 150 ms. Overload capability is defined in two profiles: standard overload allows 1.2× rated current for 60 seconds or 1.5× for 3 seconds; high overload allows 1.5× for 60 seconds or 1.85× for 3 seconds. This lets the drive handle both normal starting duty and high-breakaway-load applications. The drive is designed for both synchronous and asynchronous motors, with a speed range of 20 to 100%.

Auxiliary supplies, cooling, and environmental limits

Control power requires an external 220 V AC supply at 3 kVA; the cooling fans run on a separate 380 V AC supply. Optional external supplies are available for both. Cooling is forced convection moving 80,000 m³/h of air. The drive is rated for operation up to 1000 m altitude without derating; above that, derate 0.6% per 100 m up to 2000 m. Operating position is vertical ±10 degrees. Relative humidity range is 0–90% (0–95% optional). Vibration resistance is 4.9 m/s² from 10 to 50 Hz. Pollution degree is 2 per EN/IEC 61800-5-1, and overvoltage category is II.

Compliance, isolation, and I/O count

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation is maintained between power and control circuits. An integrated EMC filter is included. Dielectric strength is 20 kV AC between earth and power terminals. The control section provides 4 software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and 1 analogue output of the same type. There are 6 discrete inputs standard, expandable to 10.

Frequently asked questions

What motors can this drive control?

It is designed for both synchronous and asynchronous motors, covering a speed range of 20 to 100%.

What compliance documentation does Schneider provide for the ATV1200A63506060?

The drive is CE marked and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. It includes an integrated EMC filter and has 20 kV AC dielectric strength between earth and power terminals.

MPN
ATV1200A63506060