Skip to main content
Schneider Electric ATV1200A71001010

Schneider Electric ATV1200A71001010 Altivar 1200 VFD

MPN ATV1200A71001010
Obsolete

Schneider Electric Altivar 1200 ATV1200A71001010 AC drive, 5936 kW motor power, 7100 kVA apparent power, 48-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A71001010 specifications
ParameterValue
Input type48 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current410 A
IP ratingIP31 / IP42 / IP41
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1700 mm (standard efficiency)
Width9370 mm (standard efficiency)
Height3040 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

What this drive delivers for a medium-voltage motor line

The ATV1200A71001010 is a Schneider Electric Altivar 1200 AC drive rated for 5936 kW motor power with 7100 kVA apparent power — sized for large asynchronous motor loads like pumps, fans, and compressors in medium-voltage installations. It draws 410 A line current from a 2970–3630 V supply through a 48-pulse diode rectifier bridge, which keeps input harmonics low enough to meet EN/IEC 61800-3 without external filtering.

Overload profile and fault handling

Standard overload rating holds 1.2× rated current for 60 seconds and 1.5× for 3 seconds; a high-overload setting pushes to 1.5× for 60 seconds and 1.85× for 3 seconds — choose the profile that matches your motor's starting duty cycle. The drive withstands a prospective line fault of 31.5 kA for 150 ms, so it coordinates with upstream protection without requiring a separate current-limiting reactor in most medium-voltage switchgear arrangements. Ground fault protection is built into the drive, and the dielectric strength between earth and power terminals is 28 kV AC — a margin that supports direct connection to ungrounded or resistance-grounded distribution systems.

Physical footprint and installation constraints

The drive ships in a floor-standing enclosure measuring 3040 mm high by 9370 mm wide by 1700 mm deep — plan for a dedicated equipment room with a reinforced floor and overhead lifting access. Forced convection cooling moves 66400 m³/h of air; the enclosure separates internal airflows so the power cells and transformer each get their own thermal path — ducting to a plant exhaust system is recommended to avoid recirculating 80 dB noise. Power connections use M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom — coordinate the gland plate and cable tray layout before the enclosure arrives on site.

System composition and control wiring

The ATV1200A71001010 includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 24 power cells — it arrives as a near-complete drive system, not a bare chassis. Control power requires an external 220 V AC supply at 3 kVA; the internal fan supply is 380 V AC. Optional external control supply at 220 V AC/DC and optional external fan supply at 380 V AC allow separate upstream UPS feeds for the control electronics. Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and six discrete inputs (expandable to ten) handle speed reference and run commands — the I/O count is modest for a drive of this class, so plan for a remote I/O rack if the application needs more than a few signals.

Compliance and environmental limits

CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1 — covers electrical safety, EMC, and enclosure protection for industrial drive installations. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II — the drive is intended for a clean, controlled environment (no conductive dust or condensation). Relative humidity range is 0–90 % (0–95 % optional), and the drive must be mounted vertically within ±10° — factor this into the enclosure layout and HVAC design.

MPN
ATV1200A71001010