Skip to main content
Schneider Electric ATV1200A79001010 — AC Drive (VFD) 480V

Schneider ATV1200A79001010 AC Drive, 6604 kW, 7900 kVA, MV

MPNATV1200A79001010
Active

Schneider Electric Altivar 1200 series, ATV1200A79001010 medium-voltage AC drive, 6604 kW motor power, 7900 kVA apparent power, 48-pulse diode rectifier, floor-standing enclosure, 2970–3630 V supply.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A79001010 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A79001010 — Power & Output
ParameterValue
Motor power (kW)6604 kW
Continuous output current456 A (standard overload) 365 A (high overload)
Max. transient current547 A for 60 s
Apparent power7900 kVA

Input / Supply

ATV1200A79001010 — Input / Supply
ParameterValue
Rated supply voltage range10 kV +/- 10 %
Input line current490 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A79001010 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A79001010 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A79001010 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 IP41 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A79001010 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A79001010 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A79001010 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

The ATV1200A79001010 is a medium-voltage drive, not a standard 480 V unit — supply voltage limits are 2970 to 3630 V. Motor power rating is 6604 kW, with apparent power 7900 kVA. This drives large asynchronous motors in heavy industrial applications like pumps, fans, compressors, and conveyors. The 48-pulse diode rectifier front end keeps input harmonics low enough to meet IEEE 519 without external filters — a real advantage for installations near sensitive equipment or utility boundary limits. Overload capability: 1.2 × rated current for 60 s under standard overload, or 1.5 × for 60 s under high overload duty. The 1.85 × for 3 s under high overload handles short-duration peak loads without tripping.

Floor-standing enclosure — physical integration constraints

Dimensions are 1700 mm depth × 9370 mm width × 3040 mm height. This is a floor-standing enclosure requiring a dedicated concrete pad and overhead clearance for maintenance access. Separate air flows for power section and control compartment — forced convection cooling moves 110,000 m³/h of air. The ventilation system must be ducted to outside or to a conditioned space; ambient temperature and dust loading in the room directly affect drive reliability. Operating position is vertical ±10 degrees. The enclosure color is grey RAL 7032.

Power cell topology and internal composition

The drive comprises 24 power cells, a phase-shifting transformer, medium-voltage arrestors, cooling fans, and a human-machine interface. Two plinths support the enclosure. Cell-based architecture means a single failed cell can be bypassed or replaced without taking the whole drive offline — the remaining cells continue running the motor at reduced capacity. This is standard for multi-level MV drives. Dielectric strength is 28 kV AC between earth and power terminals. Electrical isolation between power and control circuits protects the low-voltage control electronics from MV transients.

Control wiring and I/O complement

Four software-configurable analogue inputs, 0–20 mA or 4–20 mA, 24 V max, 250 Ω impedance. One analogue output, same current range and impedance. Six discrete inputs standard, expandable to ten optional. External control supply is 220 V AC, 3 kVA; an optional 220 V AC/DC supply is available. Cooling fan supply is 380 V AC. Power connections are M10 bar-type terminals, clamping capacity 6 × 40 mm² for phases /R, /S, L3/T, entry from top or bottom.

CE marked. Standards compliance includes EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (IP enclosure), EN/IEC 61800-3 (EMC for drives), EN/IEC 61800-4 (drive specifications), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per EN/IEC 61800-5-1. Overvoltage category II. Operating altitude up to 1000 m standard, with derating of 0.6 % per 100 m from 1000 to 2000 m. Relative humidity 0–90 % standard, 0–95 % optional. Vibration resistance 4.9 m/s² at 10–50 Hz. Noise level 80 dB — hearing protection required within the enclosure perimeter. Prospective line short-circuit current 31.5 kA for 150 ms. Ground fault protection integrated in the drive.

Sourced to order against your BOM quantity. No stock-holding claim on this unit size; lead time depends on configuration and project schedule.

Frequently asked questions

What compliance documentation does Schneider provide for ATV1200A79001010?

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1.

MPN
ATV1200A79001010