Schneider Electric Altivar 1200 series, ATV1200A7901010 medium-voltage AC drive, 660 kW motor power, 790 kVA apparent power, 48-pulse diode rectifier input, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A7901010 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A7901010 — Power & Output
ParameterValue
Motor power (kW)660 kW
Continuous output current36 A (high overload) 46 A (standard overload)
Max. transient current55 A for 60 s
Apparent power790 kVA

Input / Supply

ATV1200A7901010 — Input / Supply
ParameterValue
Rated supply voltage range10 kV +/- 10 %
Input line current65 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A7901010 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A7901010 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A7901010 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A7901010 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A7901010 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A7901010 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Drive rating and load profile

The ATV1200A7901010 is a medium-voltage variable-speed drive from the Altivar 1200 family, rated for 660 kW motor power at 790 kVA apparent power. The input section uses a 48-pulse diode rectifier bridge, which significantly reduces line-side harmonics compared to 6- or 12-pulse topologies. Supply voltage limits are 2970–3630 V, with an output voltage equal to or less than the supply voltage. The drive is intended for asynchronous motors and provides an integrated EMC filter. Overload capability is defined by two profiles: standard overload (1.2 x In for 60 s, 1.5 x In for 3 s) and high overload (1.5 x In for 60 s, 1.85 x In for 3 s). This dual rating lets the commissioning engineer match the drive to either constant-torque or variable-torque loads.

Physical integration and cooling

The drive is assembled in a floor-standing enclosure with separate air flows for power and control sections. Overall dimensions are 3960 mm wide, 2670 mm high, and 1600 mm deep — this is a large-footprint unit requiring dedicated floor space and a reinforced foundation. Cooling is by forced convection, with a standard-efficiency fan moving 19 800 m³/h of air. The internal cooling fan supply is 380 V AC, and an external control supply of 220 V AC (3 kVA) is required. Noise level at full cooling is 80 dB — hearing protection is advisable in the drive room.

Compliance and isolation

CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation between power and control circuits is maintained, and the drive incorporates ground fault protection. Dielectric strength is 28 kV AC between earth and power terminals. Pollution degree 2 per EN/IEC 61800-5-1 applies, and overvoltage category II is specified. Prospective line short-circuit current withstand is 31.5 kA for 150 ms — this figure drives the upstream fuse or breaker selection for coordinated fault protection.

Frequently asked questions

What are the key ratings of ATV1200A7901010?

Motor power is 660 kW, apparent power is 790 kVA, supply voltage range is 2970–3630 V, and the input uses a 48-pulse diode rectifier. Overload capability is 1.2 In for 60 s (standard) or 1.5 In for 60 s (high overload).