Skip to main content
Schneider Electric ATV1200A8606666 — AC Drive (VFD) 480V

Schneider Electric ATV1200A8606666 AC Drive (VFD) 480V

MPNATV1200A8606666
Active

Schneider Electric Altivar 1200 ATV1200A8606666 medium-voltage AC drive, 719 kW motor power, 2970-3630 V supply, 36-pulse diode rectifier, 860 kVA, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A8606666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A8606666 — Power & Output
ParameterValue
Motor power (kW)719 kW
Continuous output current75 A (standard overload) 60 A (high overload)
Max. transient current90 A for 60 s
Apparent power860 kVA

Input / Supply

ATV1200A8606666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current100 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A8606666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f) Sensorless flux vector control Vector control with sensor, optional
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A8606666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A8606666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A8606666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A8606666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A8606666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Medium-voltage drive architecture for 719 kW motor loads

The Schneider Electric ATV1200A8606666 is an Altivar 1200 series medium-voltage AC drive rated for 719 kW motor power with a 2970-3630 V supply range. This is a 36-pulse diode rectifier input drive, which means the line-side harmonics are inherently low enough to meet IEEE 519 without external filters in most installations — a material advantage for a 860 kVA apparent power draw. The drive is built as a floor-standing enclosure with separate air flows for the power cells and control section, keeping electronics away from the thermal rise of the main power path. The product composition includes a phase-shifting transformer, 18 power cells, medium-voltage arrestors, cooling fans, and a human-machine interface — essentially a complete drive system in one cabinet.

Overload capability and motor protection profile

The overload withstand is specified in two duty classes: standard overload handles 1.2× In for 60 s and 1.5× In for 3 s; high overload handles 1.5× In for 60 s and 1.85× In for 3 s. This dual-profile lets the drive serve both constant-torque conveyors (standard overload) and high-breakaway-load applications like crushers or extruders (high overload) without oversizing the drive frame. Ground fault protection is integrated into the drive, and the dielectric strength between earth and power terminals is 20 kV AC. The prospective line short-circuit current withstand is 31.5 kA for 150 ms, meaning the drive's input section can ride through a fault upstream without self-destructing before the upstream protection clears.

Physical footprint and site planning constraints

The enclosure dimensions vary by efficiency variant: standard efficiency measures 3060 mm wide × 1400 mm deep × 2520 mm high; high efficiency measures 3360 mm wide × 1500 mm deep × 2670 mm high. The cooling air volume requirement is 13,200 m³/h for standard efficiency and 19,800 m³/h for high efficiency — this drives the HVAC sizing in the electrical room and must be accounted for in the ventilation design. The noise level is 80 dB, which may require hearing protection zones or acoustic enclosures in occupied spaces.

Standards compliance and regulatory acceptance

The drive carries CE marking and complies with EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (harmonic), EN/IEC 61800-5-1 (safety), EN/IEC 60204-11 (electrical equipment), and EN/IEC 60529 (enclosure protection). Pollution degree 2 per EN/IEC 61800-5-1 confirms it is rated for controlled environments only — not for conductive dust or condensation-prone locations without additional enclosure protection. The integrated EMC filter simplifies installation compliance, and the electrical isolation between power and control circuits means the 24 V control wiring can be referenced to earth without ground loop issues.

Active production and sourcing posture

For a drive of this scale (719 kW, floor-standing cabinet), the procurement lead time is driven by the transformer and power cell assembly schedule — quoted per project milestone.

MPN
ATV1200A8606666