Skip to main content
Schneider Electric ATV1200A93006363 — AC Drive (VFD) 480V

Schneider ATV1200A93006363 Altivar 1200 VFD, 7148 kW

MPNATV1200A93006363
Active

Schneider Electric Altivar 1200 ATV1200A93006363 medium-voltage AC drive, 7148 kW motor power, 8550 kVA apparent power, 2970-3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A93006363 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A93006363 — Power & Output
ParameterValue
Motor power (kW)7148 kW
Continuous output current783 A (standard overload) 626 A (high overload)
Max. transient current940 A for 60 s
Apparent power8550 kVA

Input / Supply

ATV1200A93006363 — Input / Supply
ParameterValue
Rated supply voltage range6.3 kV +/- 10 %
Input line current850 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A93006363 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A93006363 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A93006363 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP31 IP41
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A93006363 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A93006363 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A93006363 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

7148 kW motor power — medium-voltage class

The ATV1200A93006363: Rated for 7148 kW motor power with 8550 kVA apparent power, this drive sits in the medium-voltage class — supply voltage limits are 2970 to 3630 V. It is not a 480 V unit; the 36-pulse diode rectifier input keeps line-side harmonics low without an active front end. Overload capability is 1.2 In for 60 seconds (standard duty) and 1.5 In for 3 seconds — enough for normal starting and short-term overloads on large fans, pumps, or compressors. High-overload profile goes to 1.5 In for 60 s and 1.85 In for 3 s for tougher loads.

Floor-standing enclosure — site prep needed

The drive ships in a floor-standing enclosure with separate air flows for power and control sections. Physical footprint is 9770 mm wide by 3340 mm tall by 1700 mm deep — this is a room-sized installation, not a panel-mount unit. Cooling requires 100,000 m³/h of forced-convection air through the enclosure. Operating altitude above 1000 m requires derating the output current by 0.6% per additional 100 m. The enclosure must sit vertical within ±10 degrees, and ambient relative humidity is limited to 90% (95% with optional treatment).

System composition — transformer and cells included

This order code covers the complete drive system: phase-shifting transformer, medium-voltage arrestors, 18 power cells, cooling fans, and a human-machine interface. It is not a bare inverter module — the transformer and cells are integral to the 36-pulse input design. Electrical connection is via M10 screw-type bars accepting up to 6 x 40 mm² cable per phase, entry from top or bottom. The drive includes an integrated EMC filter and provides ground-fault protection on the drive side.

Frequently asked questions

What compliance standards does this drive meet?

It carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3 (EMC), EN/IEC 61800-4, and EN/IEC 61800-5-1 (safety).

MPN